2001
DOI: 10.1088/0031-9155/46/3/313
|View full text |Cite
|
Sign up to set email alerts
|

Narrow stereotactic beam profile measurements usingN-vinylpyrrolidone based polymer gels and magnetic resonance imaging

Abstract: In this work, polymer gel-MRI dosimetry (using VIPAR gels), radiographic film and a PinPoint ion chamber were used for profile measurements of 6 MV x-ray stereotactic beams of 5 and 10 mm diameter. The VIPAR gel-MRI method exhibited a linear dose response up to 32 Gy. VIPAR gels were found to resolve the penumbra region quite accurately, provided that the in-plane image resolution of the related T2-map is adequate (< or = 0.53 mm). T2-map slice thickness had no significant effect on beam profile data. VIPAR me… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
58
0

Year Published

2002
2002
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 60 publications
(60 citation statements)
references
References 34 publications
2
58
0
Order By: Relevance
“…In this study, Vinylpyrrolidone‐based polymer gels were used. A detailed description of Vinylpyrrolidone‐(VIPAR) based polymer gels, the manufacturing process, and their dosimetric characteristics can be found in the literature 17 , 18 , 19 , 20 . Polymer‐gel MRI dosimetry is based on the radiation‐induced polymerization of the gel monomers and cross‐linkers.…”
Section: Methodsmentioning
confidence: 99%
“…In this study, Vinylpyrrolidone‐based polymer gels were used. A detailed description of Vinylpyrrolidone‐(VIPAR) based polymer gels, the manufacturing process, and their dosimetric characteristics can be found in the literature 17 , 18 , 19 , 20 . Polymer‐gel MRI dosimetry is based on the radiation‐induced polymerization of the gel monomers and cross‐linkers.…”
Section: Methodsmentioning
confidence: 99%
“…The principles of the polymer gel dosimeter [25][26][27][28]30] as well as its application in clinical dosimetry have been described previously [23,24,29,[31][32][33][34].…”
Section: Determination Of the Relative Dose Distributionmentioning
confidence: 99%
“…A range of detectors broadly categorized into active (ionization chambers, solid state detectors, and plastic scintillator) and passive (TLD microcubes, gafchromic film, alanine pallets, radio photoluminescent dosimeter, and gel dosimeter) detectors have been investigated by numerous authors for small field measurements. [9101112131415161718192021222324]…”
Section: Introductionmentioning
confidence: 99%
“…[10111213] In addition, plastic scintillator detector, gel dosimeter, and radio photoluminescent dosimeter are found to be very good choice for output factor and profile measurements even for very small fields. [14151617181920]…”
Section: Introductionmentioning
confidence: 99%