NCS Report 30: Code of Practice for Quality Assurance of Brachytherapy with Ir-192 Afterloaders

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…Some articles suggested that applicator geometries may not always be consistent, 15 but the vendor's source paths are based on averaged coordinates over several samples, and in general the related uncertainty -including measurement uncertainty-is noted to be small (sub-millimeter). 56,58 Several studies and guidelines have advocated for individual applicator commissioning, 3,12,15,16 based on measurements with maximum deviations of several millimeters with manufacturer-measured source paths. For this purpose several types of applicator commissioning methodologies have been proposed in literature.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Some articles suggested that applicator geometries may not always be consistent, 15 but the vendor's source paths are based on averaged coordinates over several samples, and in general the related uncertainty -including measurement uncertainty-is noted to be small (sub-millimeter). 56,58 Several studies and guidelines have advocated for individual applicator commissioning, 3,12,15,16 based on measurements with maximum deviations of several millimeters with manufacturer-measured source paths. For this purpose several types of applicator commissioning methodologies have been proposed in literature.…”
Section: Discussionmentioning
confidence: 99%
“…13 Furthermore, "snaking" occurs when the source cable curls in the lumen as the result of friction or obstruction along the channel (Figure 1b). 12 Snaking also results in axial source path deviations. In multiple studies, geometric variations associated with these effects have been quantified.…”
Section: Related Workmentioning
confidence: 99%
“…based on a set of dynamic tests that have been recommended by the NCS CoP Report 24. 8 The system characterized with high spatial and temporal resolution demonstrated the capability to provide independent verification of dose rate, gantry speed and MLC leaf speed with high precision in both flattened and unflattened beams and with good agreement to the machine log files.…”
mentioning
confidence: 92%
“…However, due to difficulties related to film dosimetry and portal images, the delivery aspects of VMAT could not be assessed separately and with sufficient gantry-angle resolution. The NCS Code of Practice (CoP) Report 24 8 published in 2015 outlines guidelines for the commissioning and QA of VMAT using multiple machine-independent dosimetry systems. The CoP suggests that understanding the dynamic behavior of VMAT is best achieved by assessing the linac's dynamic components both individually and collectively and as a function of gantry angle.…”
Section: Introductionmentioning
confidence: 99%
“…59 Report issued by the AAPM recommends which QA checks and how often they should be performed (Kubo et al 1998). Some countries have their national guidelines (Frenière 2018, Steenhujsen et al 2018 and there is also a practical guide issued by the European Society for Therapeutic Radiology and Oncology (Venselaar and Pérez-Calatayud 2004). The programs are similar and cover mechanical checks, software checks, radiation safety checks, but none of them encompass the entire treatment delivery chain to determine absorbed dose to water experimentally and independently from TPS calculations.…”
Section: In-phantom Quality Assurance Of 192 Ir Remote Afterloading Unitsmentioning
confidence: 99%