Abstract: Objective. Prompt-gamma imaging encompasses several approaches to the online monitoring of the beam range or deposited dose distribution in proton therapy. We test one of the imaging techniques – a coded mask approach – both experimentally and via simulations.
Approach. Two imaging setups have been investigated experimentally. Each of them comprised a structured tungsten collimator in the form of a MURA mask and a LYSO:Ce scintillation detector of fine granularity. The setups differed in detector dimen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 43 publications
0
2
0
Order By: Relevance
“…Effective TOF measurement requires synchronization with the ion beam's nano pulses, which can vary during extraction, often necessitating the use of a fast-beam monitor. In addition, the Maximum Likelihood Expectation Maximization (MLEM) algorithm is also used for image reconstruction in physical collimation methods such as knifeedge or coded aperture [56,57].…”
Section: Prompt Gamma Image Processingmentioning
confidence: 99%
See 1 more Smart Citation
“…Effective TOF measurement requires synchronization with the ion beam's nano pulses, which can vary during extraction, often necessitating the use of a fast-beam monitor. In addition, the Maximum Likelihood Expectation Maximization (MLEM) algorithm is also used for image reconstruction in physical collimation methods such as knifeedge or coded aperture [56,57].…”
Section: Prompt Gamma Image Processingmentioning
confidence: 99%
“…Correlation analysis is generally used as a reconstruction algorithm that uses the auto-correlation features of coded-aperture arrays. Approaches to confirm dose distribution by measuring PG in 1D or 2D using the coded mask and MLEM image reconstruction algorithm are being considered [57]. In the beam energy range 89.5-107.9 MeV, the average distal fall-off retrieval precision was 0.72 mm, indicating that the distal fall-off location can be accurately determined.…”
Section: Prompt Gamma Imaging System With Coded-aperturementioning
confidence: 99%