1999 IEEE Transmission and Distribution Conference (Cat. No. 99CH36333) 1999
DOI: 10.1109/tdc.1999.755390
|View full text |Cite
|
Sign up to set email alerts
|

Neural network for current transformer saturation correction

Abstract: Current transformer saturation can cause protective relay misoperation or even prevent tripping. This paper presents use of artificial neural networks (ANN) to correct CT secondary waveform distortions. The ANN is trained to achieve the inverse transfer function of iron-core toroidal current transformers which are widely used in protective systems. The ANN provides a good estimate of the true (primary) current for a saturated transformer. The neural network is developed using MATLAB and trained using data from… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0
5

Year Published

2005
2005
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 25 publications
(26 citation statements)
references
References 9 publications
0
14
0
5
Order By: Relevance
“…Estas publicações envolvem apenas a estimação das correntes primárias dos TCs, como as técnicas propostas em (Pihler et al, 1997;Yu et al, 1999;Cummins et al, 2000).…”
Section: Estimadores Existentes Para a Correção Da Saturação Dos Tcsunclassified
See 2 more Smart Citations
“…Estas publicações envolvem apenas a estimação das correntes primárias dos TCs, como as técnicas propostas em (Pihler et al, 1997;Yu et al, 1999;Cummins et al, 2000).…”
Section: Estimadores Existentes Para a Correção Da Saturação Dos Tcsunclassified
“…Assim como em (Yu et al, 2001), o trabalho apresentado por (Yu et al, 1999) emprega dois conjuntos de coeficientes para as RNAs a fim de lidar com diferentes faixas de correntes de falta.…”
Section: Estimadores Existentes Para a Correção Da Saturação Dos Tcsunclassified
See 1 more Smart Citation
“…Some methods are used to avoid it, but some of the solutions can affect the cost of such a piece of equipment. The use of ANNs appears as an alternative to the correction of distorted signals by the CT saturation [20][21][22]. Figure 7 shows an energization case where the distortions caused by saturation can be clearly observed.…”
Section: The Current Transformer Saturationmentioning
confidence: 99%
“…They possess excellent features such as generalization capability, noise immunity, robustness, and fault tolerance. AI-based techniques have been used in power system protection and encouraging results are obtained [9][10][11][12][13][14][15][16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%