2021
DOI: 10.1088/1741-2552/abc7f0
|View full text |Cite
|
Sign up to set email alerts
|

NeuroDAC: an open-source arbitrary biosignal waveform generator

Abstract: Objective. Researchers are developing biomedical devices with embedded closed-loop algorithms for providing advanced adaptive therapies. As these devices become more capable and algorithms become more complex, tasked with integrating and interpreting multi-channel, multi-modal electrophysiological signals, there is a need for flexible bench-top testing and prototyping. We present a methodology for leveraging off-the-shelf audio equipment to construct a biosignal waveform generator capable of streaming pre-reco… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 32 publications
0
2
0
1
Order By: Relevance
“…Upon inspection of empirical patient and benchtop ( Stanslaski et al, 2012 ; Powell et al, 2021 ) data sets, we found that none of the time related variables associated with each packet of data could independently serve as DerivedTime. Table 4 describes why each variable cannot be used for DerivedTime.…”
Section: Methods and Resultsmentioning
confidence: 99%
“…Upon inspection of empirical patient and benchtop ( Stanslaski et al, 2012 ; Powell et al, 2021 ) data sets, we found that none of the time related variables associated with each packet of data could independently serve as DerivedTime. Table 4 describes why each variable cannot be used for DerivedTime.…”
Section: Methods and Resultsmentioning
confidence: 99%
“…packets with timestamp that is more than 24 hours away from median timestamp; packets with negative PacketGenTime; packets where PacketGenTime goes backwards in time more than 500ms; packets where elapsed PacketGenTime disagrees with elapsed timestamp by more than 2 seconds). (Powell et al 2021;Stanslaski et al 2012) data sets, we found that none of the time related variables associated with each packet of data could independently serve as DerivedTime. Table 4 describes why each variable cannot be used for DerivedTime.…”
Section: Step 3: Data Cleaned and Timestamps Alignedmentioning
confidence: 90%
“…ECG sinyali üretimi konusunda FPGA (Field Programmable Gate Array) tabanlı çalışmalar da mevcuttur ancak pratik olarak kullanım sunmayan yapılardır [14]. Sentetik EEG sinyali üretimi konusunda ise SD karttan veri okuyarak PWM tekniği ile üretim yapan bir çalışma ile ses kartı kullanılarak veritabanları kaydının tekrar oynatılmasını öneren bir çalışma mevcuttur ancak sinyallerin gösterimi bulunmamaktadır [15,16]. Sentetik EMG sinyali üretimi konusunda çalışmaya rastlanmamıştır.…”
Section: şEkil 2 Biyosinyal Tabanlı İma (Biosignal Based Hmi)unclassified