1986
DOI: 10.1021/ac00124a036
|View full text |Cite
|
Sign up to set email alerts
|

Neutral carrier based calcium(2+)-selective electrode with detection limit in the sub-nanomolar range

Abstract: The authors thank Joel Harris for his helpful comments regarding the treatment of the data. This paper is dedicated to Cheves Walling on the occasion of his 70th birthday.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
94
0
3

Year Published

1991
1991
2012
2012

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 210 publications
(104 citation statements)
references
References 30 publications
7
94
0
3
Order By: Relevance
“…The slope of the linear calibration curve was 25 mV/pCa in calibration buffers containing 10 mM EGTA, 1 mM MgCl 2 , 25 mM Tricine, 50 mM KCl, pH 7.2, and varying concentrations of CaCl 2 . This slope is close to previously published data (Schefer et al, 1986). In the range between 17 nM and 3 M the free Ca 2+ concentration was determined fluorimetrically using the ratiometric indicator dye Fura-2 (Grynkiewicz, Poenie & Tsien, 1985).…”
Section: Methodssupporting
confidence: 89%
“…The slope of the linear calibration curve was 25 mV/pCa in calibration buffers containing 10 mM EGTA, 1 mM MgCl 2 , 25 mM Tricine, 50 mM KCl, pH 7.2, and varying concentrations of CaCl 2 . This slope is close to previously published data (Schefer et al, 1986). In the range between 17 nM and 3 M the free Ca 2+ concentration was determined fluorimetrically using the ratiometric indicator dye Fura-2 (Grynkiewicz, Poenie & Tsien, 1985).…”
Section: Methodssupporting
confidence: 89%
“…Ca*+ ionophore is 1.8 mg N,N,N'N'-tetracyclohexyl-3-0x-apentanediamide (ETH129, Fluka 21193), with 118.1 mg 2-nitrophenyloctylether (o-NPOE, Fluka 73732), 1.1 mg potassium tetrakis(4-chlorophenyl)borate, and 59 mg PVC dis-solved in 2 ml of THE Inner filling solution is 0.01 M CaCl, (Schefer et al 1986). Methyltridodecylammonium nitrate (10.8 mg) (MTDDA-NO,, Fluka 91664) was used as ion exchange ligand for NO;, together with 117 mg 2nitrophenyloctylether…”
Section: Notesmentioning
confidence: 99%
“…Ca 2 + specific electrodes were calibrated using the same ionic background for calibration as used for Ca 2 + measurements. The poly (vinyl chloride) membrane of tbe electrode contained tbe recently developed neutral carrier ETH 129, which allows reliable measurements of ci+ down to the nanomolar range [18,19].…”
Section: Permeabilization Of Pancreatic Acinar Cells With Digitoninmentioning
confidence: 99%