1993
DOI: 10.1007/bf02035478
|View full text |Cite
|
Sign up to set email alerts
|

Neutron activation analysis of multiple large geological samples by in-pool irradiation using a SLOWPOKE-2 reactor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

1998
1998
2021
2021

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…These factors depend on the irradiation facility, the gamma ray detection system employed and the sample characteristics. Several calibration techniques have been proposed such as the comparative method, 16 the internal standard method 17 and theoretical modeling of the irradiation and measurement processes. 6 In this work, Monte Carlo simulation of the irradiation and counting facilities using the MCNP code was applied.…”
Section: General Discussion and Conclusionmentioning
confidence: 99%
“…These factors depend on the irradiation facility, the gamma ray detection system employed and the sample characteristics. Several calibration techniques have been proposed such as the comparative method, 16 the internal standard method 17 and theoretical modeling of the irradiation and measurement processes. 6 In this work, Monte Carlo simulation of the irradiation and counting facilities using the MCNP code was applied.…”
Section: General Discussion and Conclusionmentioning
confidence: 99%
“…Analyses of replicate test portions with masses of 50 g, grinded to 1-3 mm particles, clearly showed that even 300 g test portions were needed to reach the required variation of the between-test portion [51]. In the framework of metallic mineral survey projects, 10-15 g samples had to be analyzed to circumvent tedious homogenization procedures [52]. In view of a study on metal recovery and accounting, large-sample NAA was used for the quantification of Au and Ag in 50-100 g dross samples refined at the India Government Mint [53].…”
Section: Direct Analysis Of Materials For Which Homogenization Is Inconvenient Difficult or Close To Impossible And/or Too Expensive Due mentioning
confidence: 99%
“…Analysis of the acquired gamma spectra allows for the evaluation of the elemental composition of the sample. Absolute, comparative, k 0 and internal mono-standard based calibration techniques for LSNAA have been presented [9][10][11][12][13].…”
Section: Introductionmentioning
confidence: 99%