2021
DOI: 10.1016/j.nima.2021.165318
|View full text |Cite
|
Sign up to set email alerts
|

Neutron beam filter system for fast neutron cross-section measurement at the ANNRI beamline of MLF/J-PARC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…To solve the double-pulse beam issue in J-PARC/MLF, a neutron beam filter system has been developed and installed into the Accurate Neutron Nucleus Reaction Measurement Instrument (ANNRI) [7]. The neutron beam filter technique has been often used in nuclear reactors, to make a mono-energetic neutron beam [8,9].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…To solve the double-pulse beam issue in J-PARC/MLF, a neutron beam filter system has been developed and installed into the Accurate Neutron Nucleus Reaction Measurement Instrument (ANNRI) [7]. The neutron beam filter technique has been often used in nuclear reactors, to make a mono-energetic neutron beam [8,9].…”
Section: Methodsmentioning
confidence: 99%
“…The neutron filter materials were fabricated and tested in neutron beam experiments at J-PARC. In the test experiments, transmission neutron spectra were measured by detecting prompt rays from the 10 B(n,) 7 Li reaction placing a boron sample at the sample position. The 478-keV -rays from the 10 B(n,) 7 Li reaction were detected with a NaI(Tl) detector.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The highly radioactive sample (1 GBq) was produced by implantation of a 7 Be ion beam at the neighbouring ISOLDE facility [22]. The 7 Be(n, α) 4 He cross section was measured in the 10 meV to 10 keV neutron energy range using two 7 Be samples with an even larger total activity of 36 GBq. Each sample was set-up in a sandwich configuration with two 140 μm-thick Si-detectors placed directly in-beam [21].…”
Section: Neutron-induced Charged-particle Emission Experiments For Bi...mentioning
confidence: 99%
“…There exist several neutron time-of-flight (TOF) facilities in the world devoted to such measurements. The most active in the recent years are GELINA at JRC-Geel [1] and CERN n TOF [2] in Europe, LANSCE [3] in the USA, ANNRI [4] at J-PARK in Japan and CSNS Back-n [5] in China. This contribution presents a brief summary and update on latest experiments at CERN n TOF.…”
Section: Introductionmentioning
confidence: 99%