2019
DOI: 10.1088/1742-6596/1400/7/077015
|View full text |Cite
|
Sign up to set email alerts
|

New 50-keV neutral beam injector for the Globus-M2 spherical tokamak

Abstract: A design of the new neutral beam injector and the process of generation of a high-energy atomic beam are described in detail. The injector is fully prepared for experiments on auxiliary heating of the Globus-M2 tokamak plasma. The docking of injector with tokamak vacuum vessel is completed. The predictions for non-inductive current drive by 50 keV 1 MW neutral beam in the Globus-M2 are presented.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
2

Year Published

2022
2022
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 16 publications
0
1
0
2
Order By: Relevance
“…Глобус-М2 -компактный (большой радиус R=36 cm, малый радиус r = 24 cm, аспектное отношение A = 1.5) сферический токамак [14,15], который является модернизированной версией токамака Глобус-М [15,16]. Установка Глобус-М2 оборудована двумя [17,18] инжекторами атомов высокой энергии мощностью до 1 MW и энергией инжекции до 30 и 50 keV соответственно. В состав диагностического комплекса токамака входят два анализатора атомов перезарядки (NPA): ACORD-12 и ACORD-24M [19].…”
Section: эксперимент на токамаке глобус-м2unclassified
“…Глобус-М2 -компактный (большой радиус R=36 cm, малый радиус r = 24 cm, аспектное отношение A = 1.5) сферический токамак [14,15], который является модернизированной версией токамака Глобус-М [15,16]. Установка Глобус-М2 оборудована двумя [17,18] инжекторами атомов высокой энергии мощностью до 1 MW и энергией инжекции до 30 и 50 keV соответственно. В состав диагностического комплекса токамака входят два анализатора атомов перезарядки (NPA): ACORD-12 и ACORD-24M [19].…”
Section: эксперимент на токамаке глобус-м2unclassified
“…Toroidal magnetic field B T and plasma current I P may be increased in the new setup to 1 T and 500 kA, respectively. The diagnostic complex [5] and the neutral injection complex, which was fitted with the second injector (NI-2) [6], were upgraded in the transition to Globus-M2.…”
Section: Introductionmentioning
confidence: 99%
“…В новой установке тороидальное магнитное поле B T и ток плазмы I P могут быть увеличены до 1 T и 500 kA соответственно. Для Глобуса-М2 был обновлен диагностический комплекс [5], а также комплекс нейтральной инжекции, в который был введен второй инжектор НИ-2 [6].…”
unclassified