2012
DOI: 10.1016/j.talanta.2012.01.057
|View full text |Cite
|
Sign up to set email alerts
|

New approaches to extraction techniques in determination of 4,4′-methylenebis(2-chloroaniline) in air and water solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 13 publications
0
6
0
1
Order By: Relevance
“…W celu zwiększenia trwałości analitu i podniesienia czułości oznaczenia chromatograficznego zastosowano chlorek 3,5-dinitrobenzoilu jako substancję derywatyzującą, która według danych literaturowych [18][19][20][21][22] reaguje z aminami, dając trwałą pochodną. W trakcie badań dobrano ilość substancji derywatyzującej oraz warunki przeprowadzenia amin w substancje pochodne.…”
Section: Wynikiunclassified
“…W celu zwiększenia trwałości analitu i podniesienia czułości oznaczenia chromatograficznego zastosowano chlorek 3,5-dinitrobenzoilu jako substancję derywatyzującą, która według danych literaturowych [18][19][20][21][22] reaguje z aminami, dając trwałą pochodną. W trakcie badań dobrano ilość substancji derywatyzującej oraz warunki przeprowadzenia amin w substancje pochodne.…”
Section: Wynikiunclassified
“…To overcome this limitation, the aliphatic amines are derivatized or tagged with some strongly absorbing chromophore [98]. Except the following traditional methods, some newly fluorescence/ultraviolet reagents, such as HTFA for chromium, H(FHD) for beryllium and lanthanide, DNBC for 4,4′-methylenebis (2-chloroaniline) [99], 1-NC for alcohol ethoxylate (Brij 56), and 1-hexadecanol [100], have been developed with in vial derivatization combined with DI or HS SPME and HPLC or LC analysis.…”
Section: Fluorescence/ultraviolet Derivatizationmentioning
confidence: 99%
“…Combination of derivatization with SPME has been utilized for air and particle matters sampling in the field [116,117,153] or in the laboratory work [102,109]. Commercial SPME fibers such as PDMS, PDMS/DVB, CW/DVB, and CW/TPR have been widely used for most applications [102,109,114,116,117,153], and also, novel nanoporous polymeric (polypyrrole and polythiophene, PPy/PTh) fiber coating were used [99].…”
Section: Air and Aerosolsmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, there is a strict limit for the *Corresponding author, e-mail: xschai@gmail.com Brought to you by | New York University Bobst Library Technical Services Authenticated Download Date | 7/23/15 11:09 AM injection of a water based sample into most GC capillary columns because a significant amount of water vapor damages the columns and detectors, e.g., electron capture detector (ECD) and mass spectrometer (MS). To avoid this problem, organic solvent-extraction is a typical sample pretreatment procedure before GC testing (Tabrizi, 2007;Buszewski et al, 2012;Zhou et al, 2011), which is not only complicated and timeconsuming but it also introduces a significant error in the species quantification.…”
Section: Introductionmentioning
confidence: 99%