2019
DOI: 10.1103/physrevd.99.083005
|View full text |Cite
|
Sign up to set email alerts
|

New constraints on sterile neutrino dark matter from NuSTAR M31 observations

Abstract: We use a combined 1.2 Ms of NuSTAR observations of M31 to search for X-ray lines from sterile neutrino dark matter decay. For the first time in a NuSTAR analysis, we consistently take into account the signal contribution from both the focused and unfocused fields of view. We also reduce the modeling systematic uncertainty by performing spectral fits to each observation individually and statistically combining the results, instead of stacking the spectra. We find no evidence of unknown lines, and thus derive li… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

11
194
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 147 publications
(207 citation statements)
references
References 113 publications
(168 reference statements)
11
194
2
Order By: Relevance
“…In order to gain further insight into the parameter dependence of the constraints, we show in figure 10 how the X-ray flux from χ τ decays (where we use the median value for the χ τ lifetime from 100,000 trials) depends on m χ and m φ , for the parameter point M e L = 8, M L = 1. We also indicate where the exclusion contour lies, namely where exactly 95% of trials leads to an X-ray flux consistent with the bounds [53,54]. When the parameter M e is increased, the contours in this figure will move further up and to the left, making the excluded region smaller, while varying the parameter M will not have a significant effect on the contours.…”
Section: Additional Constraintsmentioning
confidence: 76%
See 4 more Smart Citations
“…In order to gain further insight into the parameter dependence of the constraints, we show in figure 10 how the X-ray flux from χ τ decays (where we use the median value for the χ τ lifetime from 100,000 trials) depends on m χ and m φ , for the parameter point M e L = 8, M L = 1. We also indicate where the exclusion contour lies, namely where exactly 95% of trials leads to an X-ray flux consistent with the bounds [53,54]. When the parameter M e is increased, the contours in this figure will move further up and to the left, making the excluded region smaller, while varying the parameter M will not have a significant effect on the contours.…”
Section: Additional Constraintsmentioning
confidence: 76%
“…These bounds are worked out in ref. [53] for much lighter DM particles decaying according to the mode χ ν → γν, with the result…”
Section: Dark Matter Related Constraintsmentioning
confidence: 84%
See 3 more Smart Citations