2014
DOI: 10.1103/physrevlett.112.185004
|View full text |Cite
|
Sign up to set email alerts
|

New Edge Coherent Mode Providing Continuous Transport in Long-Pulse H-mode Plasmas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

20
136
4

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 111 publications
(160 citation statements)
references
References 22 publications
20
136
4
Order By: Relevance
“…GPI has also been used to measure the quasicoherent edge oscillations [50][51][52] and edge localized modes (ELMs). 53,54 The GPI light signal will respond to any density/temperature perturbations associated with edge instabilities and also indirectly to any radial movement of edge magnetic flux surfaces which causes local density/temperature perturbations.…”
Section: What Does Gpi Measure?mentioning
confidence: 99%
See 1 more Smart Citation
“…GPI has also been used to measure the quasicoherent edge oscillations [50][51][52] and edge localized modes (ELMs). 53,54 The GPI light signal will respond to any density/temperature perturbations associated with edge instabilities and also indirectly to any radial movement of edge magnetic flux surfaces which causes local density/temperature perturbations.…”
Section: What Does Gpi Measure?mentioning
confidence: 99%
“…86 The Experimental Advanced Superconducting Tokamak (EAST) in China has installed a dual GPI system with two views located ±50 • poloidally with respect to the outer midplane, in order to evaluate the up/down symmetry of the turbulence. 51,[87][88][89] The glass fiber bundles are shielded by molybdenum tubes of 10 mm thickness to prevent darkening due to the large hard x-ray flux during lower hybrid current drive (LHCD).…”
Section: E Special Features Of Various Gpi Systemsmentioning
confidence: 99%
“…Turbulence structures in ELM-free H-mode have been observed in magnetic and density fluctuations in other devices. [10][11][12][13][14][15][16][17][18][19][20][21] Low frequency outer mode (OM) at the top of the pedestal in JET indicates a mechanism to delay the appearance of the first ELM. 10 Quasi-coherent (QC) oscillation in Alcator C-Mod is interpreted as a possible mechanism to provide radial transport through the pedestal region in enhanced D a (EDA) Hmode.…”
mentioning
confidence: 99%
“…Fluctuation spectra showing features similar to QC modes are also observed at the very edge of the plasma in several advanced regimes (H-modes [19][20][21][22], Enhanced α D H-modes [23][24][25][26][27], I-mode [28][29][30]). There is no unified explanation for these modes which present similar QC spectral signature.…”
Section: Introductionmentioning
confidence: 99%