“…In the next step, the magnetic field distributions in the designed and optimised SCFCL have been simulated using FEM, in COMSOL Multiphysics [28]. Finally, to verify the performance of the optimised SICFCL, a 3500VA prototype has been made and tested in a power system hardware model [29].…”