2013
DOI: 10.1016/j.microc.2013.06.009
|View full text |Cite
|
Sign up to set email alerts
|

New method for mercury determination in microwave digested soil samples based on cold vapor capacitively coupled plasma microtorch optical emission spectrometry: Comparison with atomic fluorescence spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
31
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 32 publications
(31 citation statements)
references
References 32 publications
0
31
0
Order By: Relevance
“…[12][13][14] One of the most interesting devices is a low-power capacitively coupled microplasma (mCCP) combined with cold vapor generation (CVG) that has been intensively explored for OES by Frentiu and co-workers. [15][16][17][18][19][20] The detection limit (DL) for Hg obtained with a mCCP is of the order of tens of ng per L (ref. 15 and 16) and can be improved by using an additional pre-concentration system.…”
Section: Introductionmentioning
confidence: 99%
“…[12][13][14] One of the most interesting devices is a low-power capacitively coupled microplasma (mCCP) combined with cold vapor generation (CVG) that has been intensively explored for OES by Frentiu and co-workers. [15][16][17][18][19][20] The detection limit (DL) for Hg obtained with a mCCP is of the order of tens of ng per L (ref. 15 and 16) and can be improved by using an additional pre-concentration system.…”
Section: Introductionmentioning
confidence: 99%
“…The construction of the plasma microtorch was detailed in previous studies. 24,31 Basically, the Ar plasma was sustained at ows of 50-200 mL min À1 and power in the range 10-20 W and 13.56 MHz frequency at the tip of a Mo microelectrode 1.25 mm diameter, 99.95% purity Goodfellow (Cambridge, UK) mounted inside a quartz tube, 5 mm i.d., 25 mm length, 160 nm cut-off, H. Baumbach & Co Ltd. (Ipswich Suffolk, UK). The admission of the Ar stream together with Hg vapour into the plasma occurs through four 750 mm diameter channels crossing the microelectrode support on a 3 mm diameter rim.…”
Section: Instrumentationmentioning
confidence: 99%
“…Also, no addition of HCl was made to stabilize Hg(II) in digests and calibration standards as was the case in the common chemical derivatization with SnCl 2 . [30][31][32]35 Instead, Hg was stabilized in 2% (v/v) HNO 3 . Sample solutions were appropriately diluted before analysis so that the depressive effects of the matrix containing metals, anions and residual organic matter was negligible.…”
Section: Matrix Effectmentioning
confidence: 99%
See 1 more Smart Citation
“…The introduction of potentially toxic elements (PTEs) in the environment is resulting either from natural (mostly geological) inputs or from anthropogenic activities (Frentiu et al 2013;Álvarez and Garrillo 2012;Esmaeili et al 2014). The presence of toxic elements in soil is often the result of emissions caused by fuel combustion, industrial activities, and the utilization of agrochemicals such as fertilizers and pesticides (Soodan et al 2014).…”
Section: Introductionmentioning
confidence: 99%