2017
DOI: 10.1038/srep46278
|View full text |Cite
|
Sign up to set email alerts
|

New method for quantification of gasotransmitter hydrogen sulfide in biological matrices by LC-MS/MS

Abstract: Hydrogen sulfide exists widely in mammalian tissues and plays a vital role in physiological and pathophysiological processes. However, striking differences with orders of magnitude were observed for the detected hydrogen sulfide concentrations in biological matrices among different measurements in literature, which lead to the uncertainty for examination the biological relevance of hydrogen sulfide. Here, we developed and validated a liquid chromatography- mass spectrometry (LC-MS/MS) method for the determinat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
58
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7
2
1

Relationship

2
8

Authors

Journals

citations
Cited by 88 publications
(63 citation statements)
references
References 50 publications
5
58
0
Order By: Relevance
“…The level of free H 2 S in RBCs was 10.5±0.8 µmol l −1 in warm normoxic turtles ( Fig. 2A), which is not far from the value reported for human RBCs measured using a MBB-based method (3.8± 1.0 µmol l −1 ) (Tan et al, 2017). RBC free H 2 S increased 2-fold in cold-acclimated turtles in normoxia but did not change further in anoxia ( Fig.…”
Section: H 2 S and Bss In Rbcsmentioning
confidence: 49%
“…The level of free H 2 S in RBCs was 10.5±0.8 µmol l −1 in warm normoxic turtles ( Fig. 2A), which is not far from the value reported for human RBCs measured using a MBB-based method (3.8± 1.0 µmol l −1 ) (Tan et al, 2017). RBC free H 2 S increased 2-fold in cold-acclimated turtles in normoxia but did not change further in anoxia ( Fig.…”
Section: H 2 S and Bss In Rbcsmentioning
confidence: 49%
“…Blood samples were collected in EDTA-containing tubes and tissues including heart, liver, kidney, spleen and lung removed. Samples were further processed according to previously reported methods and H 2 S levels determined as described by Tan et al 37 In brief, chromatography was performed using a Waters Acquity UPLC (Milford, MA, USA) equipped with a Kinetex XB-C18 column (50 mm × 2.1 mm, 2.6 μm) from Phenomenex (Torrance, CA, USA). The components were eluted by a gradient of A) 0.08% formic acid in water and B) acetonitrile and the flow rate was 0.6 mL/min.…”
Section: Pharmacokinetic Studiesmentioning
confidence: 99%
“…The blood collected was anticoagulated with heparin sodium (50 U/mL) and centrifuged (3000 rpm, 15 min) to obtain plasma. As to the H 2 S concentration of DATS@MION-PEG-LF in plasma cannot be assessed by real time H 2 Sselective microelectrode assay, therefore it was measured by HPLC method by an Agilent Technologies HPLC (1260 in nity, CA, USA) with uorescence detection (λex: 390 nm and λem: 475 nm) and an Eclipse XDB-C18 column (150 ⋅ 4.6 mm, 5 µm) within 24 h, which was previously described [7,29].…”
Section: In Vivo H 2 S Release Of Dats@mion-peg-lfmentioning
confidence: 99%