New model for heat transfer calculation during film condensation inside pipes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
25
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(25 citation statements)
references
References 24 publications
0
25
0
Order By: Relevance
“…This procedure allowing also reducing the uncertainty index up to 13 % for vertical and inclined tubes, while for horizontal tubes the average error is reduced up to 11.8 %. Table 2 offers a comparison of the index of correlation obtained when compare the experimental available data with the obtained results by means of the uses of a group of existing models in literature [15,21]. When verifying the given results, it could be verified that the proposed model evidences better values of adjustment, with an average error of the 15 %.…”
Section: Elements To Consider For the Application Of The Developed Modelmentioning
confidence: 86%
See 3 more Smart Citations
“…This procedure allowing also reducing the uncertainty index up to 13 % for vertical and inclined tubes, while for horizontal tubes the average error is reduced up to 11.8 %. Table 2 offers a comparison of the index of correlation obtained when compare the experimental available data with the obtained results by means of the uses of a group of existing models in literature [15,21]. When verifying the given results, it could be verified that the proposed model evidences better values of adjustment, with an average error of the 15 %.…”
Section: Elements To Consider For the Application Of The Developed Modelmentioning
confidence: 86%
“…In investigations carried out, the authors [15] show that Eqns. (39) to (43) can be used in the determination of a model for the calculation of the average coefficient of heat transfer by condensation, valid for any spatial configuration of the tube.…”
Section: Elements To Consider For the Application Of The Developed Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…Correlating the average cost of water protection and its average consumption, it is obtained that the best fit is given by an exponential function, with an approximation coefficient (R 2 =0,953), being described by [12,13]:…”
Section: Summary Of the Main Actions Of Mitigation Executed In Cubamentioning