“…Even when the medium has the anisotropy in the longitudinal direction, we have found that a shielded planar head [2] with a pole size of 14 Â 45 nm 2 could be used for recording. The head field distributions in DT and CT directions are shown in Fig.…”
Section: Recording Simulation and Resultsmentioning
confidence: 99%
“…This paper proposes another simple technique which could minimize the effect of magnetostatic interactions at high densities. Recording simulation with a shielded planar pole head [2] is also presented aiming at high areal densities beyond 2 Tbit/in 2 .…”
“…Even when the medium has the anisotropy in the longitudinal direction, we have found that a shielded planar head [2] with a pole size of 14 Â 45 nm 2 could be used for recording. The head field distributions in DT and CT directions are shown in Fig.…”
Section: Recording Simulation and Resultsmentioning
confidence: 99%
“…This paper proposes another simple technique which could minimize the effect of magnetostatic interactions at high densities. Recording simulation with a shielded planar pole head [2] is also presented aiming at high areal densities beyond 2 Tbit/in 2 .…”
“…Head III [11,18] employs a tapered pole, but the neck exists only in the cross-track direction. Head IV [19] has a tapered structure without a neck (zero throat height). In any of the structures, there is the option of having the trailing edge surface perpendicular to the ABS, as depicted by the figures in brackets.…”
Section: Variation Of Multi-tapered Main Polementioning
“…7, there is the optimum taper angle of around 501 in terms of the maximum field gradient. In our fabrication process of the planar head [4], an anisotropy-etched pit of a quadrangular pyramid with a taper angle of 54.71 on Si(1 0 0) surface is used as a template for the tapered main pole. Therefore, the taper angle of 551 was adopted for field calculation in this article.…”
Section: Taper Angle Effectmentioning
confidence: 99%
“…The tapered MCS head can generate larger field than the stepped one. To realize the tapered MCS head, we have proposed a shielded-planar single-pole head (abbreviated as a planar head hereafter) and its fabrication method [4]. In this paper, simulation design of the planar head with a tapered main pole by field calculation using a finiteelement method (FEM) is described.…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.