2014
DOI: 10.1107/s1600577513034796
|View full text |Cite
|
Sign up to set email alerts
|

New soft X-ray beamline BL07LSU at SPring-8

Abstract: A new soft X-ray beamline, BL07LSU, has been constructed at SPring-8 to perform advanced soft X-ray spectroscopy for materials science. The beamline is designed to achieve high energy resolution (E/ÁE> 10000) and high photon flux [>10 12 photons s À1 (0.01% bandwidth) À1 ] in the photon energy range 250-2000 eV with controllable polarization. To realise this state-of-the-art performance, a novel segmented cross undulator was developed and adopted as a light source. The details of the undulator light source and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
78
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 118 publications
(79 citation statements)
references
References 67 publications
1
78
0
Order By: Relevance
“…The ring was in TOP-UP mode. The RIXS measurement chamber of the HOR-NET endstation was used, which is illuminated by an 8 segment parallel/perpendicular figure-eight undulator [92]. The beamline monochromator is an entrance-slitless variable-included-angle Monk-Gillieson mounting type with a varied-line-spacing plane grating (VLS-PGM).…”
Section: Resonant Inelastic X-ray Scattering (Rixs) Endstation Sextamentioning
confidence: 99%
“…The ring was in TOP-UP mode. The RIXS measurement chamber of the HOR-NET endstation was used, which is illuminated by an 8 segment parallel/perpendicular figure-eight undulator [92]. The beamline monochromator is an entrance-slitless variable-included-angle Monk-Gillieson mounting type with a varied-line-spacing plane grating (VLS-PGM).…”
Section: Resonant Inelastic X-ray Scattering (Rixs) Endstation Sextamentioning
confidence: 99%
“…The same arguments hold for a segmented crossed undulator system (Tanaka and Kitamura 2004). A segmented crossed undulator scheme with eight planar horizontal and vertical figure-8 undulators and seven phase shifters has successfully been installed at SPring-8 (Yammamoto et al 2014). Recently, the idea of a segmented crossed undulator was analyzed as an option for an X-ray SASE FEL (Geloni et al 2011).…”
Section: Helically and Variably Polarizing Undulatorsmentioning
confidence: 84%
“…[40][41][42] Therefore, multilayers are commonly used as a polarizer or phase retarder in the XUV region. [43][44][45][46][47] To extend the working bandwidth of polarizers in applications, the aperiodic multilayer system can be used as an alternative for the double-polarizer scheme 48 or the laterally graded multilayer. 49 The polarization degree or phase shift has to be taken into account in the merit function during multilayer design to achieve the broadband effect.…”
Section: Broadband Multilayer Polarizermentioning
confidence: 99%