2017
DOI: 10.26896/1028-6861-2018-83-1-ii-15-20
|View full text |Cite
|
Sign up to set email alerts
|

New Spectral Systems Based on MAES Analyzers

Abstract: Ïðåäñòàâëåí îáçîð ñïåêòðàëüíûõ êîìïëåêñîâ äëÿ àòîìíî-ýìèññèîííîãî ñïåêòðàëüíîãî àíàëèçà, ïðîèçâîäèìûõ êîìïàíèåé «ÂÌÊ-Îïòîýëåêòðîíèêà»: «Ãðàíä-Ãëîáóëà», «Ãðàíä-Êðèñòàëë» è «Ýêñïðåññ»-äëÿ ïðÿìîãî àòîìíî-ýìèññèîííîãî ñïåêòðàëüíîãî àíàëèçà òâåðäûõ ìåòàëëè÷åñêèõ è ïîðîøêîâûõ ïðîá; «Ãðàíä-Ïîòîê»-äëÿ ýêñïðåññ-àíàëèçà ïîðîøêîâ ìåòîäîì ïðîñûïêè-âäóâàíèÿ; «Ãðàíä-Ýêñïåðò» è «Ôàâîðèò»-äëÿ ýêñïðåññ-àíàëèçà ìåòàëëîâ è ñïëàâîâ; óñòàíîâêè èñêðîâîãî ïðîáîîòáîðà «Àñïåêò»-äëÿ àíàëèçà ìåòàëëè÷åñêèõ îáðàçöîâ ñ ïîìîùüþ ÈÑÏ-ÀÝÑ è ÈÑ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0
2

Year Published

2017
2017
2020
2020

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 0 publications
0
1
0
2
Order By: Relevance
“…A Grand spectrometer 24 equipped with a concave diffraction grating (2400 lines/mm) and two multichip photodiode arrays, which were a key component of a multichannel analyzer of emission spectra (MAES), allowed spectrum registration in two spectral ranges: 185 -350 and 385 -470 nm. The MAES system is supplied with ATOM software package, which allows spectral data processing: measurement of analytical signals with background correction, construction of calibration curves and calculation of element concentrations.…”
Section: Plasmatronmentioning
confidence: 99%
“…A Grand spectrometer 24 equipped with a concave diffraction grating (2400 lines/mm) and two multichip photodiode arrays, which were a key component of a multichannel analyzer of emission spectra (MAES), allowed spectrum registration in two spectral ranges: 185 -350 and 385 -470 nm. The MAES system is supplied with ATOM software package, which allows spectral data processing: measurement of analytical signals with background correction, construction of calibration curves and calculation of element concentrations.…”
Section: Plasmatronmentioning
confidence: 99%
“… íàñòîÿùåå âðåìÿ äëÿ îïðåäåëåíèÿ ìèêðîïðèìåñåé â ïîðîøêîâûõ ïðîáàõ ìåòîäîì ñöèíòèëëÿöèîííîé àòîìíî-ýìèññèîííîé ñïåêòðîìåòðèè (ÑÀÝÑ) âñå øèðå èñïîëüçóþò ñïåêòðàëüíûé êîìïëåêñ «Ãðàíä-Ïîòîê» [1] ñ ðåãèñòðàöèåé ïîñëåäîâàòåëüíîñòåé ñïåêòðîâ áûñòðîäåéñòâóþùèìè ìíîãîêàíàëüíûìè àíàëèçàòîðàìè ýìèññèîííûõ ñïåêòðîâ (ÌÀÝÑ) [2]. Âñëåäñòâèå íåðàâíîìåðíîñòè ðàñïðåäåëåíèÿ îïðåäåëÿåìûõ ýëåìåíòîâ, íàïðèìåð áëàãîðîäíûõ ìåòàëëîâ, â ÷àñòèöàõ ïðîáû ïîëó÷åííûå çàâèñèìîñòè èíòåíñèâíîñòè ñïåêòðàëüíûõ ëèíèé ýòèõ ýëåìåíòîâ îò âðåìåíè ñîäåðaeàò âñïûøêè (ñöèíòèëëÿöèè) èíòåíñèâíîñòè.…”
unclassified
“…Îïûò ïîêàçûâàåò, ÷òî ïðè ýêñïëóàòàöèè ñïåêòðàëüíûõ êîìïëåêñîâ ÀÝÑ-ÈÑÏ â àíàëèòè÷åñêèõ ëàáîðàòîðèÿõ äîëãîâå÷íîñòü èñ-òî÷íèêà ÈÑÏ ÷àñòî ïðåâûøàåò äîëãîâå÷íîñòü ñïåêòðîìåòðà. Äëÿ çàìåíû âûøåäøåãî èç ñòðîÿ ñïåêòðîìåòðà ìîaeíî èñïîëüçîâàòü îòå÷åñòâåííûé ñïåêòðîìåòð «Ãðàíä», ðåãèñòðàöèÿ ñïåêòðîâ â êîòîðîì îñóùåñòâëÿåòñÿ ãèáðèäíûìè ñáîðêàìè ëèíååê ôîòîäåòåêòîðîâ [2].…”
unclassified