2022
DOI: 10.1364/ao.462059
|View full text |Cite
|
Sign up to set email alerts
|

Noise analysis in Stokes parameter reconstruction for division-of-focal-plane polarimeters

Abstract: The division-of-focal-plane (DoFP) polarimeter can quickly and effectively obtain the polarization information of light in real time, where Stokes parameter reconstruction is a critical issue. Many reconstruction methods have been proposed to address this; however, their performance tends to degrade in the presence of noise. Thus, it is significant to clarify the noise-induced error in Stokes parameter reconstruction. In this work, we investigate the link between the noise-introduced error and the reconstructi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 27 publications
0
1
0
Order By: Relevance
“…35 The denoising algorithms were, in turn, expanded upon to include non-gaussian noise sources., 36 and an overall analysis of the impact of noise on reconstruction/demosaicing algorithms was performed. 37 Making use of the correlation between superpixels, others have used guided filtering to remove aliasing effects. 38 The newest forms of interpolation make use of residual interpolation with a range of flavors: edge-aware, intensity-guided, Modified Newton, or iterative.…”
Section: Introductionmentioning
confidence: 99%
“…35 The denoising algorithms were, in turn, expanded upon to include non-gaussian noise sources., 36 and an overall analysis of the impact of noise on reconstruction/demosaicing algorithms was performed. 37 Making use of the correlation between superpixels, others have used guided filtering to remove aliasing effects. 38 The newest forms of interpolation make use of residual interpolation with a range of flavors: edge-aware, intensity-guided, Modified Newton, or iterative.…”
Section: Introductionmentioning
confidence: 99%
“…In contrast to the Stokes mask-based polarization camera, the DoFP system incorporates a micro-lens array with the sensor. Leveraging advanced image reconstruction methods, the DoFP system achieves high imaging quality 18 . It has been applied in three dimensional HSI color space imaging and skylight polarization measurement 19,20 .…”
mentioning
confidence: 99%