2009
DOI: 10.1103/physrevlett.103.050402
|View full text |Cite
|
Sign up to set email alerts
|

Noise-Immune Conjugate Large-Area Atom Interferometers

Abstract: We present a pair of simultaneous conjugate Ramsey-Bordé atom interferometers (SCI) using large (20hk)-momentum transfer (LMT) beam splitters, wherehk is the photon momentum. Simultaneous operation allows for common-mode rejection of vibrational noise. This allows us to surpass the enclosed space-time area of previous interferometers with a splitting of 20hk by a factor of 2,500.Among applications, we demonstrate a 3.4 ppb resolution in the fine structure constant and discuss tests of fundamental laws of physi… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

4
137
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
7
1

Relationship

5
3

Authors

Journals

citations
Cited by 105 publications
(141 citation statements)
references
References 39 publications
4
137
0
Order By: Relevance
“…The combination of this result with the measurement and the calculation of the electron anomaly provides the most stringent test of QED. In the future, the sensibility of the interferometer can be increased by using a larger area interferometer [22,23] and the experiment can be improved to reduce the correction due to the Gouy phase and the wave front curvature and divide the uncertainty by a factor of two. Then a main limitation will be the uncertainty of the mass ratio m Rb /m e .…”
mentioning
confidence: 99%
“…The combination of this result with the measurement and the calculation of the electron anomaly provides the most stringent test of QED. In the future, the sensibility of the interferometer can be increased by using a larger area interferometer [22,23] and the experiment can be improved to reduce the correction due to the Gouy phase and the wave front curvature and divide the uncertainty by a factor of two. Then a main limitation will be the uncertainty of the mass ratio m Rb /m e .…”
mentioning
confidence: 99%
“…Two vertical velocity cuts with a pulse duration t s of 400 µs are performed. Signals due to gravity and vibrations are cancelled by measuring the phase difference of the two interferometers using ellipse fitting [6]. The laser system driving the interferometer is similar to the one described in [5,6,30].…”
mentioning
confidence: 99%
“…This enables state-of-the-art measurements of the fine structure constant α [1] and will help realize the expected new definition of the kilogram in terms of the Planck constant [2,3]. Using multiphoton Bragg diffraction [4,5] and simultaneous operation of conjugate interferometers [6], the phase difference has been increased to Φ = 16n 2 ω r T (where the factor of 16 arises from taking the phase difference of the two interferometers), and Earth's gravity and vibrations have been canceled. Unfortunately, however, Bragg diffraction causes a diffraction phase [2,[7][8][9], which has been the largest systematic effect in high-sensitivity atom interferometers using this technique [2].…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Light atomic species have been used in supersonic atomic-beam interferometers [25,26], but remain difficult to cool below the recoil temperature T r where the average thermal speed equals the recoil velocity. This makes it impossible to spatially resolve the interferometer outputs, which is required for direct rejection of common-mode inertial signals with phase extraction methods [27][28][29].…”
mentioning
confidence: 99%