Nominal Size and Taper Analysis of Novel Metallurgy NiTi Files

Abstract: Objective: The aim of this investigation was to assess the nominal tip diameter, taper and true pilot tip length of three nickel-titanium (NiTi) rotary files before and after use. Methods: Three brands of NiTi files of size 25.08 were evaluated: ProTaper Uni-versal (Dentsply Tulsa Specialties, Tulsa, USA), Channels PT (Insight Endo for Henry Schein, Melville, NY) and ProTaper Gold (Dentsply Tulsa Specialties), with ten files from each brand (total n=30). Scanning electron microscope (SEM) images of the files a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(6 citation statements)
references
References 12 publications
1
5
0
Order By: Relevance
“…4 The absence of accuracy was verified from the results of the present study for all groups of finishing files and cones of groups F1, F2, F3 and F4. A similar result was observed by Chesler et al 9 when evaluating the ProTaper F3 files and by Islambasic et al 11 when evaluating ProTaper F2 files. It was also verified that there was a tendency for the files to have lower actual diameters in groups F1, F4 and F5 and for the cones to have actual diameters higher than nominal.…”
Section: Discussionsupporting
confidence: 84%
See 4 more Smart Citations
“…4 The absence of accuracy was verified from the results of the present study for all groups of finishing files and cones of groups F1, F2, F3 and F4. A similar result was observed by Chesler et al 9 when evaluating the ProTaper F3 files and by Islambasic et al 11 when evaluating ProTaper F2 files. It was also verified that there was a tendency for the files to have lower actual diameters in groups F1, F4 and F5 and for the cones to have actual diameters higher than nominal.…”
Section: Discussionsupporting
confidence: 84%
“…3 Although the ProTaper Universal ® system is widely used, few studies have evaluated the actual diameters of its files and cones. 4,[9][10][11] In order to measure the files' and cones' D 0 diameters, a profile projector was used as it allows accurate and reliable measurements. 10,13 However, other studies have used methods such as digital imaging obtained by an optical microscope, 14 a measuring microscope, 3,8 a scanning electron microscope 11 and a digital caliper.…”