Non-communication protection method for meshed and radial distribution networks with synchronous-based DG

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
48
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 43 publications
(49 citation statements)
references
References 28 publications
0
48
0
1
Order By: Relevance
“…V recl,F is locally measured using the potential transformer installed at the main substation. –The exponential function prevents the operating time of recloser reduces to zero when a fault occurs at the beginning of the feeder. In Jamali and Borhani‐Bahabadi, due to use of V recl,F in the numerator of modification term, the recloser operating time is zero for the zero voltage condition, as shown in Table . –Since the modified operating time of recloser should be proportional to the voltage drop at the beginning of feeder, the recloser should operate fast for the faults occurred near its location due to significant voltage drop while in the case of a fault far from the recloser location, its operating time increases. To satisfy this principle, the term of 1− V recl,F should be included in the exponential function of modification term.…”
Section: Operating Principles Of Fuse and Reclosermentioning
confidence: 99%
See 4 more Smart Citations
“…V recl,F is locally measured using the potential transformer installed at the main substation. –The exponential function prevents the operating time of recloser reduces to zero when a fault occurs at the beginning of the feeder. In Jamali and Borhani‐Bahabadi, due to use of V recl,F in the numerator of modification term, the recloser operating time is zero for the zero voltage condition, as shown in Table . –Since the modified operating time of recloser should be proportional to the voltage drop at the beginning of feeder, the recloser should operate fast for the faults occurred near its location due to significant voltage drop while in the case of a fault far from the recloser location, its operating time increases. To satisfy this principle, the term of 1− V recl,F should be included in the exponential function of modification term.…”
Section: Operating Principles Of Fuse and Reclosermentioning
confidence: 99%
“…The study results are shown in Table . OCBMT strategy enhances the performance of current‐based modification term proposed in Shah and Bhalja while OVBMT strategy enhances the performance of voltage‐based modification terms proposed in Saleh et al and Jamali and Borhani‐Bahabadi . In comparison with Shah and Bhalja, OCBMT strategy allows for more PV sources without protection miscoordination.…”
Section: Performance Evaluationmentioning
confidence: 99%
See 3 more Smart Citations