2006
DOI: 10.2472/jsms.55.95
|View full text |Cite
|
Sign up to set email alerts
|

Non-Destructive Observations of Internal Microstructures of Materials by Scanning Electron-Induced Acoustic Microscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…The radiographic inspection equipment, in fact, is the non-destructive way, while it has lower resolution compared with TEM or SEM. Then, we have developed the scanning electron-induced acoustic microscope (SEAM) (Shibutani et al, 2006;Koyama and Shibutani, 2012). SEAM has been originally proposed by Cargill (Cargill, 1980), Brandis & Rosencwaig (Brandis and Rosencwaig, 1980) and Rosencwaig (Rosencwaig, 1982) as one of the methods of non-destructive detection of internal micro-defects and structures.…”
Section: Introductionmentioning
confidence: 99%
“…The radiographic inspection equipment, in fact, is the non-destructive way, while it has lower resolution compared with TEM or SEM. Then, we have developed the scanning electron-induced acoustic microscope (SEAM) (Shibutani et al, 2006;Koyama and Shibutani, 2012). SEAM has been originally proposed by Cargill (Cargill, 1980), Brandis & Rosencwaig (Brandis and Rosencwaig, 1980) and Rosencwaig (Rosencwaig, 1982) as one of the methods of non-destructive detection of internal micro-defects and structures.…”
Section: Introductionmentioning
confidence: 99%
“…The radiographic inspection equipment is, in fact, the non-destructive way, meanwhile it has lower resolution compared with TEM or scanning Proceedings of ATEM'11 2 ATEM'11, September 19-21, 2011, Kobe, Japan electron microscope (SEM). These drawbacks and advantages motivate us to develop the scanning electron-induced acoustic microscope (SEAM) (1) . SEAM has originally been proposed by Cargill (2) and Brandis & Rosencwaig (3) independently as one of the prospective candidates of non-destructive detection of micro-defects.…”
Section: Introductionmentioning
confidence: 99%
“…SEAM has successfully been applied to the non-destructive observation of delamination of integrated circuit (4) , interface of multi-layered film (5) , phase transition od ceramics (6) , internal fracture of hard-coated material (7) and so on. And our own-built SEAM has provided martensitic phase transformation and grain boundary without any chemical etching (1) besides.…”
Section: Introductionmentioning
confidence: 99%
“…The radiographic inspection equipment is, in fact, the non-destructive way, meanwhile it has lower resolution compared with TEM or scanning electron microscope (SEM). These drawbacks and advantages motivate us to develop the scanning electron-induced acoustic microscope (SEAM) (1) . SEAM has originally been proposed by Cargill (2) and Brandis & Rosencwaig (3) independently as one of the prospective candidates of non-destructive detection of micro-defects.…”
Section: Introductionmentioning
confidence: 99%