2020
DOI: 10.1039/c9tb02757b
|View full text |Cite
|
Sign up to set email alerts
|

Non-equilibrium organosilane plasma polymerization for modulating the surface of PTFE towards potential blood contact applications

Abstract: We report a novel and facile organosilane plasma polymerization method designed to improve the surface characteristics of poly(tetrafluoroethylene) (PTFE).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
34
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 19 publications
(34 citation statements)
references
References 34 publications
0
34
0
Order By: Relevance
“…After incubation, the stained membranes were evaluated by live fluorescence image analysis for comparison. 36 Platelet Adhesion. To assess the coating's effects on platelet adhesion, human whole blood platelets (Innovative Research, MI) were seeded (density, 6 ×10 6 platelets/mL) with uncoated and coated membranes and incubated at 37 °C for 30 min in a 24-well plate.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…After incubation, the stained membranes were evaluated by live fluorescence image analysis for comparison. 36 Platelet Adhesion. To assess the coating's effects on platelet adhesion, human whole blood platelets (Innovative Research, MI) were seeded (density, 6 ×10 6 platelets/mL) with uncoated and coated membranes and incubated at 37 °C for 30 min in a 24-well plate.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…Then, each sample was stained with calcein-AM (0.75 μL/mL PBS) and evaluated by live fluorescence image analysis. 36 In Vivo Device Implantation. All protocols were approved by the Institutional Animal Care and Use Committee (IACUC) in compliance with Animal Care regulations.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…22,23 According to various immobilization methods of heparin, activating inert catheter materials such as polyurethane is a key issue for surface modification. A series of strategies have been performed to enrich the surface with active functional groups such as hydroxyl, amine, carboxyl or sulfhydryl groups, mainly including plasma treatment/polymerization, [24][25][26][27] surface grafting and silanization. [28][29][30][31][32] However, the application of these strategies involving multiple steps or specific devices remains controversial in terms of in vivo biocompatibility or clinical practice.…”
Section: Introductionmentioning
confidence: 99%