Abstract:Abstract. Two different kinds of bulk-Si comb-drive actuators are designed in this work: initial overlap comb-drive actuator and non-initial overlap comb-drive actuator. They are fabricated by a simple post-CMOS bulk micromachining process. A cascade folded beam is designed to achieve large displacement at low driving voltages. And non-initial overlap and unequal wide comb fingers are used to reduce the side instability and improve the pull-in voltage. The measurement results show that the non-initial overlap … Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.