2015
DOI: 10.1016/j.talanta.2015.01.029
|View full text |Cite
|
Sign up to set email alerts
|

Non-invasive quantitative micro-PIXE–RBS/EBS/EBS imaging reveals the lost polychromy and gilding of the Neo-Assyrian ivories from the Louvre collection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 17 publications
(5 citation statements)
references
References 30 publications
0
4
0
1
Order By: Relevance
“…MSI images acquired in 4 spectral bands [22]: ultraviolet [23] (360-400 nm) [24], UV show us previous conservation to select non treated area for analysis [25] visible (400-780 nm), and infrared [26] (780-1700 nm). infrared used for detecting and visualize under drawings in paintings [27] IRF (Infrared Fluorescence) [28] visible-induced infrared luminescence (VIL) and infrared (IR)) presented in this study.…”
Section: Technical Photography (Tp)mentioning
confidence: 99%
“…MSI images acquired in 4 spectral bands [22]: ultraviolet [23] (360-400 nm) [24], UV show us previous conservation to select non treated area for analysis [25] visible (400-780 nm), and infrared [26] (780-1700 nm). infrared used for detecting and visualize under drawings in paintings [27] IRF (Infrared Fluorescence) [28] visible-induced infrared luminescence (VIL) and infrared (IR)) presented in this study.…”
Section: Technical Photography (Tp)mentioning
confidence: 99%
“…A total of 16 carved ivories of the Département des Antiquités orientales, Musée du Louvre (Paris, France), have been analysed by means of optical microscopy, UV photography, X-ray radiography and micro-PIXE imaging (Fontan and Reiche 2011;Albéric et al 2015). Additionally, 13 objects kept in the Badische Landesmuseum (Karlsruhe, Germany) could be studied by Full Field Synchrotron micro X-Ray Fluorescence (FF-SR-µXRF) with a new 3D imaging X-ray detector, the Colour X-ray Camera (CXC) at the synchrotron facility ANKA (Karlsruhe, Germany).…”
Section: Insights Into the Relationship Of The Employed Raw Materialmentioning
confidence: 99%
“…Might surface degradation be a marker of previous surface treatments? Scientific analysis revealed a significant presence of copper oxide on the frame, indicating that its original colour probably was blue or green (Fontan / Reiche 2011;Affanni 2011b;Fontan 2013;Reiche et al 2013;Albéric et al 2014;Spadavecchia et al 2014). …”
Section: Documentation Protocolmentioning
confidence: 99%