2017
DOI: 10.1088/1757-899x/172/1/012030
|View full text |Cite
|
Sign up to set email alerts
|

Non-invasive Self-Care Anemia Detection during Pregnancy Using a Smartphone Camera

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…Anggraeni and Fatoni [31] introduced a non-invasive anemia detection system based on a digital image of palpebral conjunctiva captured by a smartphone camera. Digital image of the inferior palpebral conjunctiva was captured with an Asus Zenphone-2 Laser smartphone, ambient lighting without flash, and then color-corrected with white paper.…”
Section: Related Workmentioning
confidence: 99%
“…Anggraeni and Fatoni [31] introduced a non-invasive anemia detection system based on a digital image of palpebral conjunctiva captured by a smartphone camera. Digital image of the inferior palpebral conjunctiva was captured with an Asus Zenphone-2 Laser smartphone, ambient lighting without flash, and then color-corrected with white paper.…”
Section: Related Workmentioning
confidence: 99%
“…The most frequently used smartphones are developed by Apple, Samsung, Motorola, Google, HTC, Sony, and Asus, where the camera sensor is used to capture videos or images. The accuracy level was deemed to be reliable in each of the studies listed in Multimedia Appendix 1 [50,51,54,55,[57][58][59][60][61][62][63][64]. Data commonly captured by a smartphone were obtained from two main body sites: the fingertip and eyelid.…”
Section: Smartphone As a Poc Toolmentioning
confidence: 99%
“…Digital images of the palpebral conjunctiva can provide information to measure the level of Hb in a noninvasive manner [80]. Anggraeni et al [57] built a regression model using the digital images of 20 participants' eyelids along with white paper images captured at the same time by Asus ZenFone 2, and estimated the Hb concentration, which correlated highly with clinically measured Hb levels (r=0.92). Among the three color pixels of a palpebral conjunctiva image, the red color intensity showed better performance than the green and blue pixel intensities in this study.…”
Section: Palpebral Conjunctivamentioning
confidence: 99%
“…In [42], a study was presented that has the ambitious goal of providing health resources to developing countries, where it is difficult to diagnose anemia with traditional methods; in [43] the estimate of the concentration of hemoglobin in the blood is discussed to limit the problem of postpartum hemorrhage caused by anemia, which occurs mostly in Africa and Asia. Both studies are based on the analysis of the color of the conjunctiva, in the second case taking the photos in ambient lighting, without flash, with a white paper positioned next to the eye to standardize white.…”
Section: Estimation Of Anemia By Analyzing the Eyelid Conjunctivamentioning
confidence: 99%