1996
DOI: 10.1109/58.542050
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive real-time multipoint temperature control for ultrasound phased array treatments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
79
0
2

Year Published

1999
1999
2018
2018

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 143 publications
(83 citation statements)
references
References 13 publications
2
79
0
2
Order By: Relevance
“…In particular, papers by Sun and Ying [23], Seip, Simon, Ebbini and coworkers [54][55][56], Maass-Moreno, Damianou and coworkers [57][58][59] and this group [29,60,61] have reported the changes in received ultrasonic signals due to changes in ultrasonic tissue characteristics with temperature. These changes have been investigated both theoretically and in vitro with an eye towards using these signals for non-invasive monitoring of thermal therapy.…”
Section: Ultrasonic Measurement Of Temperaturementioning
confidence: 99%
See 1 more Smart Citation
“…In particular, papers by Sun and Ying [23], Seip, Simon, Ebbini and coworkers [54][55][56], Maass-Moreno, Damianou and coworkers [57][58][59] and this group [29,60,61] have reported the changes in received ultrasonic signals due to changes in ultrasonic tissue characteristics with temperature. These changes have been investigated both theoretically and in vitro with an eye towards using these signals for non-invasive monitoring of thermal therapy.…”
Section: Ultrasonic Measurement Of Temperaturementioning
confidence: 99%
“…Temperature estimation using these effects is based on measuring displacements in the direction of propagation z, which can be related to changes in temperature iT(z) according to [39,55,56,62] ÁT ðzÞ ¼ c 0 =2ð À Þ Â tðzÞ=z ð1Þ…”
Section: Echo Shiftsmentioning
confidence: 99%
“…2 Ultrasound can be applied for real-time temperature measurements with good spatial resolution and high penetration depth, but the temperature sensitivity is low. [3][4][5] Magnetic resonance imaging has the advantages of high resolution and sensitivity, but it is expensive, bulky, and slow. 6,7 Therefore, an accurate, noninvasive, real-time temperature measurement method needs to be developed.…”
Section: Introductionmentioning
confidence: 99%
“…Em geral, esse monitoramento é realizado com a Ressonância Magnética (RM) [3], que é uma técnica cara. Entretanto, tal procedimento não pode ser utilizado no caso da hipertermia magnética com nanopartículas [4][5][6][7][8][9][10], já que esta nanoterapia depende da rotação dos momentos magnéticos das nanopartículas sob ação de campo alternado.…”
Section: Introductionunclassified
“…Atualmente, estimar a temperatura de modo não invasivo utilizando ondas de ultrassom é um metodos estudado por três categorias, estimativas usando alterações no coeficiente de atenuação acustica [18], os que estimam usando a mudança na energia retroespalhada [17], e os que usando a mudança na velocidade do som e expansão térmica [3,[12][13][14][15][16]. Em qualquer que seja a categoria utilizada para a estimativa de temperatura, o sucesso da técnica se baseia na capacidade de conseguir medir precisamente os parâmetros mencionados com relação a temperatura para que o equipamento possa ser adequadamente calibrado [11].…”
Section: Introductionunclassified