Abstract: Doppler echocardiography was performed in 136 patients with a normally functioning prosthetic valve in the aortic (n = 59), mitral (n = 74) and tricuspid (n = 3) positions. These included patients with St. Jude (n = 82), Björk-Shiley (n = 18), Beall (n = 13), Starr-Edwards (n = 7) or tissue (n = 16) valves. Peak and mean pressure gradients across the prostheses were measured using the simplified Bernoulli equation. The prosthetic valve orifice (PVO, in square centimeters), only in the mitral position, was calc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
40
1
1

Year Published

1987
1987
2004
2004

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 161 publications
(47 citation statements)
references
References 18 publications
5
40
1
1
Order By: Relevance
“…These results presented earlier compare favorably with those of other mechanical valves of similar design [20,21]. When comparing patients with different valve sizes, peak velocity and pressure gradients are inversely related to annulus diameter.…”
Section: Commentsupporting
confidence: 72%
“…These results presented earlier compare favorably with those of other mechanical valves of similar design [20,21]. When comparing patients with different valve sizes, peak velocity and pressure gradients are inversely related to annulus diameter.…”
Section: Commentsupporting
confidence: 72%
“…[3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22] It decreased to 5Ϯ3 mmHg (Pϭ. 000) soon after T and to 4Ϯ2 mmHg (Pϭ0.000 versus baseline, PϭNS versus end of T infusion) at 24 hours.…”
Section: Effects Of T On Pressure Gradient and Opening Angle (Figure 2)mentioning
confidence: 99%
“…[17][18][19][20][21][22][23] Since the introduction of TEE, ultrasound imaging has become the most used test in case of prosthesis dysfunction. This change happened without convincing scientific evidence of the superiority of 1 technique over the other.…”
Section: Role Of F and Doppler Echocardiography In Diagnosis Of Pvtmentioning
confidence: 99%
“…This fact might account for the better correlation and diagnostic value in our study, since myo cardial infarctions tend to increase QRS duration with no increase in LV mass [15,16].…”
Section: Discussionmentioning
confidence: 64%