13th International Conference on Medical Information Processing and Analysis 2017
DOI: 10.1117/12.2285978
|View full text |Cite
|
Sign up to set email alerts
|

Normal human gait patterns in Peruvian individuals: an exploratory assessment using VICON motion capture system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 0 publications
0
4
0
1
Order By: Relevance
“…The gait performance of each study participant using the traditional lower-limb orthosis and the knee robotic orthosis was measured and compared. Kinematic gait parameters were measured in the laboratory by utilizing a 12-camera motion capture system (Vicon Nexus, Oxford Metrics) 14 . The study participants were instructed to perform a random sequence of walking trials with 1) the existing lock knee orthosis and 2) the knee robotic orthosis.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The gait performance of each study participant using the traditional lower-limb orthosis and the knee robotic orthosis was measured and compared. Kinematic gait parameters were measured in the laboratory by utilizing a 12-camera motion capture system (Vicon Nexus, Oxford Metrics) 14 . The study participants were instructed to perform a random sequence of walking trials with 1) the existing lock knee orthosis and 2) the knee robotic orthosis.…”
Section: Methodsmentioning
confidence: 99%
“…The Vicon system adopted in the gait analysis session of this study was composed of a 12-camera motion capture system (Vicon Nexus, Oxford Metrics) that was used to capture the kinematic gait pattern of the participants. Forty reflective markers were attached to each participant, and the obtained gait data were computed on the basis of the Plug-in-Gait model of the Vicon system 14 . The participants could have about six strides on each walking trial with the walkway for capturing the gait data by the Vicon system in the gait laboratory.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Frecuentemente estas tecnologías son usadas junto con otros desarrollos como sistemas de realidad virtual o aumentada y dispositivos portables (wearables). Entre sus principales aplicaciones se encuentran los análisis biomecánicos, estudios clínicos [17], rehabilitación, animación multimedia para producciones audiovisuales y rendimiento deportivo. Las tecnologías para el análisis de movimiento se dividen a su vez, de acuerdo al tipo de dispositivo que usen para medir el desplazamiento y la ubicación de las articulaciones.…”
Section: Ecuación De Búsquedaunclassified