2014
DOI: 10.1002/rcs.1604
|View full text |Cite
|
Sign up to set email alerts
|

Novel computer-assisted preoperative planning system for humeral shaft fractures: report of 43 cases

Abstract: The novel CAPP system was efficient and reliable, providing excellent clinical outcomes for treatment of humeral shaft fractures using locking plates.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1
1

Relationship

3
6

Authors

Journals

citations
Cited by 18 publications
(12 citation statements)
references
References 46 publications
0
12
0
Order By: Relevance
“…The 3D structures of each bone consisted of Lisfranc joints and were reconstructed using a shaded surface display (SSD) with a reconstruction interval of 0.625 mm and a density threshold of 150H. A 3D interactive and automatic segmentation technique was applied to distinguish all component bones [1518]. According to the literatures about the criteria of the reduction for Lisfranc injuries [7, 8, 11], postoperative evaluation of the reduction was performed using the below-described criteria.…”
Section: Methodsmentioning
confidence: 99%
“…The 3D structures of each bone consisted of Lisfranc joints and were reconstructed using a shaded surface display (SSD) with a reconstruction interval of 0.625 mm and a density threshold of 150H. A 3D interactive and automatic segmentation technique was applied to distinguish all component bones [1518]. According to the literatures about the criteria of the reduction for Lisfranc injuries [7, 8, 11], postoperative evaluation of the reduction was performed using the below-described criteria.…”
Section: Methodsmentioning
confidence: 99%
“…A previous study has proved that an efficient and reliable system for computer-assisted preoperative planning (CAPP) provides excellent clinical outcomes in the treatment of humeral shaft fractures with locking plates [17]. Therefore, we presumed that the CAPP system could also provide a new approach with respect to preoperative design in PFNA-II treatment of intertrochanteric femoral fractures and lower the learning difficulty of this surgical procedure for beginners.…”
Section: Introductionmentioning
confidence: 99%
“…So up to now, 3D CT has not been extensively applied in posterior malleolar fracture evaluation nor has it been reported in a study on large sample [22,23]. With the upgrading of computer technology, an efficient system for computer-assisted preoperative planning has been developed [24][25][26]. e use of computer technology enables multilevel and multiangle evaluation of fracture planes.…”
Section: Introductionmentioning
confidence: 99%
“…e use of computer technology enables multilevel and multiangle evaluation of fracture planes. Surgeons can also perform a virtual operation efficiently and conveniently, including reducing the fracture fragments and selecting a suitable internal fixation device [24,25]. With this technology, detailed evaluation and accurate measurement of posterior malleolar fracture may be promoted to a higher level.…”
Section: Introductionmentioning
confidence: 99%