2008
DOI: 10.1016/j.bios.2007.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Novel highly-performing immunosensor-based strategy for ochratoxin A detection in wine samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
96
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 122 publications
(97 citation statements)
references
References 24 publications
1
96
0
Order By: Relevance
“…Two ionisable moieties of OTA, monoanion (OTA À ) and dianion (OTA 2À ) are present at neutral pH at the pK a s of the carboxyl and phenol groups in OTA. The presence of ochratoxin A and its diversity in nature are due to the ability of OTA-producing filamentous fungi, Aspergillus ochraceus and Penicillium verrucosum, growing on a wide range of substrates under varying climatic and storage conditions [4]. High temperatures, moisture and unseasonal rains during harvest and flash floods lead to fungal proliferation and production of Ochratoxin A [5].…”
Section: Introductionmentioning
confidence: 99%
“…Two ionisable moieties of OTA, monoanion (OTA À ) and dianion (OTA 2À ) are present at neutral pH at the pK a s of the carboxyl and phenol groups in OTA. The presence of ochratoxin A and its diversity in nature are due to the ability of OTA-producing filamentous fungi, Aspergillus ochraceus and Penicillium verrucosum, growing on a wide range of substrates under varying climatic and storage conditions [4]. High temperatures, moisture and unseasonal rains during harvest and flash floods lead to fungal proliferation and production of Ochratoxin A [5].…”
Section: Introductionmentioning
confidence: 99%
“…Immunosensors using enzymatic labels (e.g., HRP, AP) tend to be sensitive because of the potential for significant amplification provided by the enzyme. They also tend to use commonly available optical or electrochemical readers that are relatively inexpensive [32][33][34][35][36]. The downside to these immunoassays is that most require additional steps (e.g., washing, adding substrate and/or mediator) that are avoidable with certain other formats.…”
Section: Discussionmentioning
confidence: 99%
“…Monoclonal (MAb) antibodies (clone 5G9) exhibited at least one order of Immunosensors have generated high expectations of providing fast and highly sensitive detection of food contaminants. In a recent study, two indirect competitive enzyme-linked immunosorbent assay (ELISA) strategies were used for the development of electrochemical immunosensors based on different OTA immobilization techniques for the detection of OTA in wine [32]. Immunosensors based on the immobilization of avidin/biotin-OTA conjugate seemed to have enhanced performance characteristics compared to those based on the adsorption of bovine serum albumin (BSA)-OTA conjugate on screen-printed electrode's (SPE) surface.…”
Section: Biosensors For the Detection Of Ochratoxin A In Wine Beer Amentioning
confidence: 99%
“…OTA concentration: 1 = 0 ng/mL; 2 = 0.5 ng/mL; 3 = 1 ng/mL; 4 = 2.5 ng/mL; 5 = 5 ng/mL; and 6 = 10 ng/mL. stabilization of wine samples and adequate antigen-antibody binding, the pH value must be adjusted to 7.0 (Ngundi et al, 2005;Prieto-Simon, Campas, Marty, & Noguer, 2008).…”
Section: Detection Of Ota In Red Winementioning
confidence: 99%