Novel Potentiometric Solid‐contact Electrode for the Determination of Fe2+ Ions via MWCNTs‐Gemifloxacin Composite

Abstract: A novel electrode was fabricated for the quantitation of Fe2+ ion. It was based on the covalent attachment of the gemifloxacin molecule (the recognition element) to the surface of MWCNTs to be incorporated as an electroactive material. Linear response of Fe2+ ions was found in the concentration range of 1×10−2 mol L−1 to 1×10−8 mol L−1 with a Nernstian slope of 30.37 ±0.3 (mV/decade) and attained a stable response within 5 s. The sensor exhibited LOD value of 4.8×10−9 mol L−1. It was applied in the monitoring … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 17 publications
1
5
0
Order By: Relevance
“…Dynamic light scattering (DLS) measurements were performed using the Zetasizer NanoZS instrument, model ZEN3600 (Malvern Instruments, Malvern, Worcestershire, UK). The size distribution of the polymeric assemblies in the polymer solutions (1.05 mg•mL −1 of POX 1.2 kDa, 1.75 mg•mL −1 of POX 2 kDa, and 4.1 mg•mL −1 of POX 4.7 kDa in deionized water) was carried at temperatures of 10,15,20,25,27,29,30,31,33,35,37, and 39 • C. The hydrodynamic radius (RH) was measured at a scattering angle of θ = 173 • , and the data were processed with the Repes algorithm. All POX solutions were filtered before measurement using a 0.45 µm PVDF syringe filter.…”
Section: Characterization Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Dynamic light scattering (DLS) measurements were performed using the Zetasizer NanoZS instrument, model ZEN3600 (Malvern Instruments, Malvern, Worcestershire, UK). The size distribution of the polymeric assemblies in the polymer solutions (1.05 mg•mL −1 of POX 1.2 kDa, 1.75 mg•mL −1 of POX 2 kDa, and 4.1 mg•mL −1 of POX 4.7 kDa in deionized water) was carried at temperatures of 10,15,20,25,27,29,30,31,33,35,37, and 39 • C. The hydrodynamic radius (RH) was measured at a scattering angle of θ = 173 • , and the data were processed with the Repes algorithm. All POX solutions were filtered before measurement using a 0.45 µm PVDF syringe filter.…”
Section: Characterization Methodsmentioning
confidence: 99%
“…It was also reported that ISE was used for the determination of cations/anions and was also used for pharmaceutical compounds [ 23 , 24 , 25 , 26 ]. Currently, there have been only limited reports on the potentiometric detection of Fe 3+ ions in the literature [ 27 , 28 , 29 ]. Abdallah et al developed a new potentiometric sensor for the quantification of Fe 2+ ions via an MWCNTs-Gemifloxacin composite in the range of 10 −2 mol L −1 to 10 −8 mol L −1 with a Nernstian slope of 30.37 ± 0.3 (mV/decade).…”
Section: Introductionmentioning
confidence: 99%
“…Studies on the construction of Fe 2+ -SCISEs using MWCNTs-gemifloxacin composite were described in publication [172]. The resulting sensor had a wide range of linearity (1 × 10 −2 -1 × 10 −8 M) with a slope of 30.37 ± 0.3 mVdec −1 and a fast response time (5 s).…”
Section: Composites Based On Carbon Nanomaterials With Other Materialsmentioning
confidence: 99%
“…For example, MWCNTs-gemifloxacin composite based ISE has been presented for detection of Fe 2+ ions in multivitamin tablets, tap water, and milk samples. 27 In another report, Mohamed et al reported an Fe 2+ -ISE based on a graphite–gold nanoparticles-polypyrrole nanocomposite and applied it in spiked water samples. 28 Recently, Ismail et al developed a polyaniline–graphite composite electrode modified with 2,2 bipyridyl and 1,10-phenanthroline-5-amine for Fe 2+ detection in serum samples.…”
Section: Introductionmentioning
confidence: 99%