2014
DOI: 10.1016/j.jphotochem.2014.07.026
|View full text |Cite
|
Sign up to set email alerts
|

Novel sensitive sensors for Cu2+ and optical switching of photochromic dithienylethene derivatives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(7 citation statements)
references
References 51 publications
0
7
0
Order By: Relevance
“…On the basis of the selective displacement fluorescent behavior of the receptor ( S )-1, OR logic function , was investigated in the existence of Ni 2+ and Al 3+ selected as two inputs by combining two different wavelengths (λ max = 380 nm (or) 400 nm) in the emission mode. The truth table and OR logic gates are illustrated in Figure .…”
Section: Resultsmentioning
confidence: 99%
“…On the basis of the selective displacement fluorescent behavior of the receptor ( S )-1, OR logic function , was investigated in the existence of Ni 2+ and Al 3+ selected as two inputs by combining two different wavelengths (λ max = 380 nm (or) 400 nm) in the emission mode. The truth table and OR logic gates are illustrated in Figure .…”
Section: Resultsmentioning
confidence: 99%
“…The result indicated that the coordinate sites of compound 1 for Ca 2+ and Cu 2+ different. In our previous work, we demonstrated that Cu 2+ was coordinated at the imidazole part (9). Therefore, we deduced that the coordinate of diarylethene 1 with Ca 2+ should be situated at the two nitrogen atoms of the phenanthroline moiety. )…”
Section: Fluorescence Changes Of Diarylethene 1o Induced By Ionsmentioning
confidence: 90%
“…Cu 2+ is ranked third of the essential heavy metals in the human body below zinc and iron (2), However, Cu 2+ exhibits toxicity at high concentrations and can cause serious neurodegenerative diseases such as Wilson disease (3), Alzheimer's disease (4), and familial amyotrophic lateral sclerosis (5,6). Therefore, the design of a suitable colorimetric sensor with specific response to Cu 2+ has been studied extensively (7)(8)(9)(10)(11)(12). In addition, the calcium ion is one of the most important second messengers in cell signaling pathways.…”
Section: Introductionmentioning
confidence: 99%
“…In general, these probes have restricted motion in the vesicles and fluoresce from LE state, whereas fluoresce from ICT state in micelles. Recently such type of donor-acceptor conjugated systems are also used as a sensor for detection of ions for various other applications [43][44][45].…”
Section: Volume 3 Issue 5 -2016mentioning
confidence: 99%