Novel systems for the application of isolated tensile, compressive, and shearing stimulation of distraction callus tissue

Abstract: BackgroundDistraction osteogenesis is a procedure widely used for the correction of large bone defects. However, a high complication rate persists, likely due to insufficient stability during maturation. Numerical fracture healing models predict bone regeneration under different mechanical conditions allowing fixation stiffness optimization. However, most models apply a linear elastic material law inappropriate for the transient stresses/strains present during limb lengthening or segment transport. They are al… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
22
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(24 citation statements)
references
References 35 publications
(25 reference statements)
2
22
0
Order By: Relevance
“…In this context it has to be noted that remains unclear whether the new bone formation is linked to the inflammatory process which occurs within hours after implant insertion (Bielemann, Marcello‐Machado, Bel Cury, & Faot, ; Bosshardt et al, ; Insua, Monje, Wang, & Miron, ). As this inflammatory process provokes bone remodeling (Ma et al, ), the movement of the implant might have induced a distraction of the newly formed woven bone (Meyers, Schulke, Ignatius, & Claes, , ). However, further research is needed to investigate the associated molecular patterns and also potential relationships to early implant failures.…”
Section: Discussionmentioning
confidence: 99%
“…In this context it has to be noted that remains unclear whether the new bone formation is linked to the inflammatory process which occurs within hours after implant insertion (Bielemann, Marcello‐Machado, Bel Cury, & Faot, ; Bosshardt et al, ; Insua, Monje, Wang, & Miron, ). As this inflammatory process provokes bone remodeling (Ma et al, ), the movement of the implant might have induced a distraction of the newly formed woven bone (Meyers, Schulke, Ignatius, & Claes, , ). However, further research is needed to investigate the associated molecular patterns and also potential relationships to early implant failures.…”
Section: Discussionmentioning
confidence: 99%
“…In an animal experiment employing sheep, a distraction device ( Fig 1 ) incorporating a mobile hydroxyapatite-coated titanium plate (CelGen AG, Zug, Switzerland) was mounted to the right tibia [ 8 ]. Postoperatively, the animals were subjected to a combined protocol of lateral callus distraction and subsequent cyclic, compressive stimulation of the regenerate tissue through movement of the titanium plate ( Fig 2A ).…”
Section: Methodsmentioning
confidence: 99%
“…A custom-designed system, which allowed a protocol of lateral callus distraction and subsequent cyclic compressive, tensile, or shearing stimulation of the regenerate tissue [ 12 ] was applied in an ovine model to the anteromedial tibial surface of the right hind leg.…”
Section: Methodsmentioning
confidence: 99%
“… A modified system was used for shear movements described in detail in a previous publication [ 12 ]. …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation