2006
DOI: 10.1109/tps.2006.881297
|View full text |Cite
|
Sign up to set email alerts
|

Numerical Analysis of a Pulsed Compact LTD System for Electron Beam-Driven Radiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
19
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(19 citation statements)
references
References 24 publications
0
19
0
Order By: Relevance
“…ises to be, at a given pinch current and implosion time, more efficient and reliable. Seminal work by Kovalchuk et al [80,83,88,92], Bastrikov et al [81,90], Kim et al [74,82,85,87,89,91,94,101], McDaniel and Spielman [84], Mazarakis et al [76,79,86,102], Rose et al [93,100], Vizir et al [95], Leckbee et al [96,97,99], and Rogowski et al [98] have led to impressive advances in LTD technology.…”
Section: Introductionmentioning
confidence: 99%
“…ises to be, at a given pinch current and implosion time, more efficient and reliable. Seminal work by Kovalchuk et al [80,83,88,92], Bastrikov et al [81,90], Kim et al [74,82,85,87,89,91,94,101], McDaniel and Spielman [84], Mazarakis et al [76,79,86,102], Rose et al [93,100], Vizir et al [95], Leckbee et al [96,97,99], and Rogowski et al [98] have led to impressive advances in LTD technology.…”
Section: Introductionmentioning
confidence: 99%
“…The Linear Transformer Driver (LTD) is a relatively new pulsed power architecture based on the induction voltage adder (IVA) [6][7][8]. In both systems (IVA or LTD) voltage adder cells are stacked in series and voltage is added along a coaxial vacuum transmission line.…”
Section: Option 2: Linear Transformer Drivermentioning
confidence: 99%
“…The capability of the Cygnus accelerators is well documented and some spare hardware exists which would significantly reduce cost. The second option is based on the Linear Transformer Driver (LTD) technology developed at Sandia and the Russian High Current Electronics Institute [6][7]. A 2-2.5-MV LTD is being built and tested at Sandia.…”
Section: Introductionmentioning
confidence: 99%
“…A linear-transformer-driver (LTD) module is an induction voltage adder that is powered by circuits located within the cavities of the adder [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20]. Since an LTD module can be designed to provide single-stage electrical-pulse compression and impedance matching, such modules are attractive candidates as prime-power sources for nextgeneration pulsed-power accelerators .…”
Section: Introductionmentioning
confidence: 99%