Abstract:Abstract. According to the actual structure and working condition of a high-flow gas pressure control valve in cycle power generation project, 3-D model based on Fluid-structure Interaction (FSI) is set up. A combined calculation for turbulent flow and structure response of high-flow control valve was established, using two-way coupling method to study the effect of FSI of valve on flow field pressure. The results of flow field pressure and pressure drop are analysed, comparing with the calculated results with… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.