2019
DOI: 10.1016/j.engstruct.2018.10.001
|View full text |Cite
|
Sign up to set email alerts
|

Numerical insights on the seismic risk of confined masonry towers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
3
1

Relationship

2
6

Authors

Journals

citations
Cited by 43 publications
(15 citation statements)
references
References 32 publications
0
15
0
Order By: Relevance
“…For the non-linear static numerical analyses of EL3, the elastic properties of masonry (E and G) are derived from a tailored assessment based on a dynamic identification, while the values of non-linear parameters of the numerical models are chosen in light of a critical study of values experimentally obtained by other authors for similar masonry types (Bartoli et al 2013(Bartoli et al , 2019. This choice is dictated by the fact that the visual investigation of the masonry, together with the comparison with the parameters experimentally determined for the nearby Torre Grossa (Bartoli et al 2013), suggested the use of strength parameters values higher than the ones proposed by MIT (2009).…”
Section: Mechanical Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…For the non-linear static numerical analyses of EL3, the elastic properties of masonry (E and G) are derived from a tailored assessment based on a dynamic identification, while the values of non-linear parameters of the numerical models are chosen in light of a critical study of values experimentally obtained by other authors for similar masonry types (Bartoli et al 2013(Bartoli et al , 2019. This choice is dictated by the fact that the visual investigation of the masonry, together with the comparison with the parameters experimentally determined for the nearby Torre Grossa (Bartoli et al 2013), suggested the use of strength parameters values higher than the ones proposed by MIT (2009).…”
Section: Mechanical Parametersmentioning
confidence: 99%
“…Given its complex setting, with surrounding buildings, the Cugnanesi tower represents a comprehensive reference case for the critical discussion of the framework set up by the IG. Indeed, even if the scientific literature has produced robust approaches for the systematic seismic assessment of masonry towers, the proper evaluation of the effects of the interaction between the tower and its connected lower structures, when the tower is not an isolated structure, is still an open question (Bartoli et al 2019).…”
Section: Introductionmentioning
confidence: 99%
“…To date, there have been conspicuous advances in simulating the response of ancient masonry structures, mainly with the aim of determining the ultimate vertical loads and capacity with respect the lateral seismic actions. For example, among other studies, modeling criteria for ancient bridges may be found in Laterza et al (2017b) andD'Amato et al (2017), while for ancient churches they are reported in Pelà et al (2009); Formisano and Marzo (2017); Betti et al (2018);D'Amato et al (2018), Formisano et al (2018); Fuentes et al (2019); Ramirez et al (2019), and Lopez et al (2019), and they are discussed for towers in Shakya et al (2016); Bartoli et al (2018) and Sarhosis et al (2018). Models of general historical buildings are discussed in Caprili et al (2017) and Milani et al (2018), while detailed study on in-situ tests may be found, among the others, in Krstevska et al (2010); Bartoli et al (2013), and Luchin et al (2018).…”
Section: Introductionmentioning
confidence: 99%
“…From both the analysis (modal, pushover, and non-linear dynamic) and the comparison with the existing damage, it was concluded that the presence of adjacent structural elements influence the seismic behavior of the tower and modify the tower's crack pattern. In addition, the numerical assessment of the seismic risk of the Chigi tower in San Gimignano (Italy) was presented by Bartoli et al (2019), where the presence of a continuous constraint on three sides not only may reduce the effective slenderness and the period but might also produce local stress concentration and pounding phenomena. Three different levels of investigation and resolution were used according to the Italian guidelines.…”
Section: Introductionmentioning
confidence: 99%