2017
DOI: 10.1016/j.egypro.2017.12.719
|View full text |Cite
|
Sign up to set email alerts
|

Numerical Simulation of Soil Thermal Response Test with Thermal-dissipation Corrected Model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
2

Year Published

2019
2019
2020
2020

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 3 publications
0
2
0
2
Order By: Relevance
“…In-situ measurements by thermal response test (TRT) are the dominant common approach to determine these values and the borehole thermal resistance. The TRT methodology is injecting/extracting a constant rate of heat energy at a constant fluid flow rate inside BHX, and the inlet and outlet fluid temperature is recorded for continuous 48 hours [5][6][7][8][9]. The Infinite Line Source Model (ILSM) is the typical model to calculate and predict the soil properties; the LSM in an infinite homogenous medium, borehole and grouting is not accounted for in the ILS but is added through the borehole resistance term [10].…”
Section: Introductionmentioning
confidence: 99%
“…In-situ measurements by thermal response test (TRT) are the dominant common approach to determine these values and the borehole thermal resistance. The TRT methodology is injecting/extracting a constant rate of heat energy at a constant fluid flow rate inside BHX, and the inlet and outlet fluid temperature is recorded for continuous 48 hours [5][6][7][8][9]. The Infinite Line Source Model (ILSM) is the typical model to calculate and predict the soil properties; the LSM in an infinite homogenous medium, borehole and grouting is not accounted for in the ILS but is added through the borehole resistance term [10].…”
Section: Introductionmentioning
confidence: 99%
“…In general, the research evaluating indoor thermal comfort is carried out by direct survey of the observation location (Santoso, 2012), using thermal technology (Kyriaki et al, 2015). Intended to determine the accuracy of the temperature parameters observed (Ma et al, 2017). Everyone expect to live in a thermal environment where they feel comfortable.…”
Section: Introductionmentioning
confidence: 99%
“…A retirada de amostras do campo para posterior análise em laboratório, através do ensaio da sonda-agulha, apresenta custos elevados e problemas operacionais. Como alternativa, há a execução de ensaios in situ do tipo TRT, que oferecem resultados representativos dos parâmetros térmicos de solos (LHENDUP et al, 2014;MA et al, 2017).…”
Section: Ensaio Teste Resposta Térmica (Trt)unclassified
“…A eficiência do conjunto também aumenta com o número de circuitos de tubos em "U". O autor acredita que o programa numérico desenvolveu satisfatoriamente os cenários analisados, uma vez que os resultados experimentais e numéricos de temperatura do fluido na saída (Tout) dos tubos de PEAD foi inferior a 0,5 ᵒ C Ma et al (2017). realizaram um ensaio TRT por furo trocador de calor de diâmetro 0,15 m e comprimento 117 m em um solo arenoso da região de Binzhou, na província de Shandong, China.…”
unclassified