2007
DOI: 10.1016/j.jacc.2007.03.040
|View full text |Cite
|
Sign up to set email alerts
|

Obesity Is a Major Determinant of Radiation Dose in Patients Undergoing Pulmonary Vein Isolation for Atrial Fibrillation

Abstract: Obese patients receive more than twice the effective radiation dose of normal-weight patients during AF ablation procedures. Obesity needs to be considered in the risk-benefit ratio of AF ablation and should prompt further measures to reduce radiation exposure.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

8
90
1
6

Year Published

2008
2008
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 183 publications
(105 citation statements)
references
References 32 publications
8
90
1
6
Order By: Relevance
“…Otyłość powiązano również z większą dawką promieniowania i częstością występowania powikłań podczas ablacji AF [302,303]. Warto zauważyć, że poprawa objawowa po przezcewnikowej ablacji AF u otyłych pacjentów wydaje się podobna jak u pacjentów o prawidłowej masie ciała [298].…”
Section: Ablacja Przezcewnikowa U Otyłych Pacjentówunclassified
“…Otyłość powiązano również z większą dawką promieniowania i częstością występowania powikłań podczas ablacji AF [302,303]. Warto zauważyć, że poprawa objawowa po przezcewnikowej ablacji AF u otyłych pacjentów wydaje się podobna jak u pacjentów o prawidłowej masie ciała [298].…”
Section: Ablacja Przezcewnikowa U Otyłych Pacjentówunclassified
“…1,1241,1242,1243,1244,1245,1246,1247 Fluoroscopy is required for most components of the procedure, including catheter placement, positioning a multielectrode catheter into the CS, double transseptal catheterization, PV angiography, and LA ablation. A survey of the writing group members reveals that two-thirds use single-plane fluoroscopy, whereas one-third employ biplane.…”
Section: Section 10: Complicationsmentioning
confidence: 99%
“…One study reported a mean fluoroscopy time >60 minutes, with corresponding higher effective radiation doses in obese patients. 1244,1246 By using a vest containing 50–60 dosimeters to measure peak skin doses (PSDs), another study reported a mean PSD of 1.0 ± 0.5 Gy in the right anterior oblique and 1.5 ± 0.4 Gy in the left anterior oblique projection, during a mean fluoroscopy time of 67.8 ± 21 minutes. 1245 They estimated an overall lifetime risk of excess fatal malignancies normalized to 60 minutes of fluoroscopy of 0.07% for women and of 0.1% for men.…”
Section: Section 10: Complicationsmentioning
confidence: 99%
“…The effective radiation dose from radiographic and fluoroscopic examinations for patients with a high BMI can be much higher. 22,23 For patients undergoing CT, a high BMI often limits which radiation dose reduction techniques can be used. If patients with a high BMI are scanned with the same technique as patients with a lower BMI, the amount of incident radiation will be suboptimal and the resultant images will typically appear grainy or "noisy.…”
Section: Radiation Dose From Imaging Examinationsmentioning
confidence: 99%