2017
DOI: 10.1177/1469066717693851
|View full text |Cite
|
Sign up to set email alerts
|

Observed adducts on positive mode direct analysis in real time mass spectrometry – Proton/ammonium adduct selectivities of 600-sample in-house chemical library

Abstract: In this study, direct analysis in real time adduct selectivities of a 558 in-house high-resolution mass spectrometry sample library was evaluated. The protonated molecular ion ([M + H]) was detected in 462 samples. The ammonium adduct ion ([M + NH]) was also detected in 262 samples. [M + H] and [M + NH] molecular ions were observed simultaneously in 166 samples. These adduct selectivities were related to the elemental compositions of the sample compounds. [M + NH] selectivity correlated with the number of oxyg… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
6
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 26 publications
1
6
0
Order By: Relevance
“…However, the protonated form of 3′-SL was still more abundant than other adduct ions ([M + NH 4 ] + , [M+Na] + , and [M+K] + ), and there was still a considerable abundance of insource fragment ions ( m/z 454.16). The relative abundance of protonated molecules and the other adduct ions of different OS may be related to the specific OS molecule properties, such as elemental composition [ 47 ].…”
Section: Resultsmentioning
confidence: 99%
“…However, the protonated form of 3′-SL was still more abundant than other adduct ions ([M + NH 4 ] + , [M+Na] + , and [M+K] + ), and there was still a considerable abundance of insource fragment ions ( m/z 454.16). The relative abundance of protonated molecules and the other adduct ions of different OS may be related to the specific OS molecule properties, such as elemental composition [ 47 ].…”
Section: Resultsmentioning
confidence: 99%
“…Ammonium tends to form adducts with hydrophobic neutral compounds, especially for the species having oxygen atoms ( Hua and Jenke, 2012 ; Sugimura et al, 2017 ). We selected ammonium as an adduct for pro-EGCG.…”
Section: Discussionmentioning
confidence: 99%
“…DART-MS data were recorded in positive mode between 200 and 400 °C with He or N 2 as the carrier gas. In some cases, [2 M + H] + and [M + NH 4 ] + species were also observed …”
Section: Methodsmentioning
confidence: 99%
“…In some cases, [2 M + H] + and [M + NH 4 ] + species were also observed. 68 Gas Chromatography−Mass Spectrometry. GC-MS analysis was performed on a Hewlett-Packard Agilent 6890−5973 GC-MS workstation.…”
Section: ■ Conclusionmentioning
confidence: 99%