2007 IEEE Canada Electrical Power Conference 2007
DOI: 10.1109/epc.2007.4520342
|View full text |Cite
|
Sign up to set email alerts
|

Off-Grid Diesel Power Plant Efficiency Optimization and Integration of Renewable Energy Sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…Other studies have also concluded that typically diesel gen sets have a high economic and environmental cost (Katiraei & Abbey, 2007;Kim & Leng, 1999;Lautier et al, 2007;Lipman, 1994). A common design flaw for diesel based electricity systems in off-grid communities are its excess installed capacity (Schofield, 2011;Weis & Ilinca, 2010).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Other studies have also concluded that typically diesel gen sets have a high economic and environmental cost (Katiraei & Abbey, 2007;Kim & Leng, 1999;Lautier et al, 2007;Lipman, 1994). A common design flaw for diesel based electricity systems in off-grid communities are its excess installed capacity (Schofield, 2011;Weis & Ilinca, 2010).…”
Section: Discussionmentioning
confidence: 99%
“…Various studies have used the HOMER model to evaluate and design hybrid systems based not only on wind but also on hydro, solar, and grid connection in remote communities (Ibrahim, Younès, Ilinca, Dimitrova, & Perron, 2010;Katiraei & Abbey, 2007;Lautier et al, 2007;. In addition to these steps of efficient operation of gen sets and integration of renewable energy in the electricity mix, the HOMER model can also be used to evaluate how the demand side can be managed to balance with its supply.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Action Dispatch strategy Diesel Diesel starts At specific battery level that is determined by the state of charge (SOC) or battery terminal voltage At specific site load power which is measured as a percentage of the diesel generator or inverter rated capacity At specific renewable output power as a percentage of the peak power of the PV generator After a specific time period Diesel generator operation At fixed, at the full power rating Diesel meeting the entire load and charging the battery if required Diesel meeting the base load with battery supplying the transient load Diesel stops At specific battery level that is determined by the SOC or battery terminal voltage At specific site load power which is measured as a percentage of the diesel generator or inverter rated capacity At specific renewable output power as a percentage of the peak power of the PV generator At specific power transferred to battery At specific diesel operating power level After a specific time period At specific battery level At specific diesel operating power level At specific PV output power frequency and grid voltage for the control of the AC bus (AC grid) [111][112][113][114][115][116].…”
Section: Elementmentioning
confidence: 99%
“…Therefore, they must provide power to the community through their own means. A widely used technology to provide most of the power and ancillary services is the diesel generator [1]. This is implemented mostly due to its established and well known characteristics.…”
Section: Introductionmentioning
confidence: 99%