Olefin Metathesis in Continuous Flow Reactor Employing Polar Ruthenium Catalyst and Soluble Metal Scavenger for Instant Purification of Products of Pharmaceutical Interest

Abstract: In recent years, the development of continuous-flow reactors has attracted growing attention from the synthetic community. Moreover, findings in the precise control of the reaction parameters and improved mass/heat transfer have made the flow setup an attractive alternative to batch reactors, both in academia and industry, enabling safe and easy scaling-up of synthetic processes. Even though a majority of the pharmaceutical industry currently rely on batch reactors or semibatch reactors, many are integrating f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(16 citation statements)
references
References 75 publications
2
12
0
Order By: Relevance
“…2, 131.6, 130.7, 128.1, 126.5, 74.9, 48.5, 38.5, 23.0. Presented analytical data are consistent with literature (Rodriguez et al, 2020;Toh et al, 2021). 2, 136.2, 125.9, 125.8, 124.7, 124.2, 123.2, 122.3, 111.6, 54.0, 53.4; melting point: 216 C. Presented analytical data are consistent with literature (Nienałtowski et al, 2020b).…”
Section: Synthesis Of Ru9barfsupporting
confidence: 88%
See 2 more Smart Citations
“…2, 131.6, 130.7, 128.1, 126.5, 74.9, 48.5, 38.5, 23.0. Presented analytical data are consistent with literature (Rodriguez et al, 2020;Toh et al, 2021). 2, 136.2, 125.9, 125.8, 124.7, 124.2, 123.2, 122.3, 111.6, 54.0, 53.4; melting point: 216 C. Presented analytical data are consistent with literature (Nienałtowski et al, 2020b).…”
Section: Synthesis Of Ru9barfsupporting
confidence: 88%
“…13 C NMR (101 MHz, CDCl 3 ) d 156.2, 156. 1, 137.2, 137.1, 131.7, 131.4, 128.4, 128.3, 127.8, 127.7, 127.6, 127.4, 66.9, 66.7, 52.5, 52.3, 39.4, 39.1, 34.0, 33.9, 27.1, 26.9, 19.6, 19.1.Presented analytical data are consistent with literature (Szczepaniak et al, 2019;Toh et al, 2021). 2, 131.6, 130.7, 128.1, 126.5, 74.9, 48.5, 38.5, 23.0.…”
Section: Synthesis Of Ru9barfsupporting
confidence: 88%
See 1 more Smart Citation
“…The removal of gaseous products in organometallic flow chemistry is relevant to the deployment of alkene metathesis processes in flow, where the inability to remove ethene from micro-reactor tubing compromises conversion. 13…”
Section: Resultsmentioning
confidence: 99%
“…The removal of gaseous products in organometallic flow chemistry is relevant to the deployment of alkene metathesis processes in flow, where the inability to remove ethene from micro-reactor tubing compromises conversion. 13 It is important to note that the intensities of infrared absorbances vary with the symmetry of each vibrational mode, such that peak height or integrated area are inappropriate for estimating relative concentrations of species of different symmetry (O h -[W(CO) 6 ] vs. C 4v -[W(THF)(CO) 5 ]) but useful for an estimation of conversion. To provide a more practically useful assay of productive conversion, the sample was dispensed into the theoretical equimolar amount of triphenylphosphine (Scheme 1).…”
Section: Dalton Transactionsmentioning
confidence: 99%