2018
DOI: 10.1021/acs.analchem.8b01492
|View full text |Cite
|
Sign up to set email alerts
|

On-Capillary Surface-Enhanced Raman Spectroscopy: Determination of Glutathione in Whole Blood Microsamples

Abstract: Oxidative stress monitoring in the neonatal period supports early outcome prediction and treatment. Glutathione (GSH) is the most abundant antioxidant in most cells and tissues, including whole blood, and its usefulness as a biomarker has been known for decades. To date, the available methods for GSH determination require laborious sample processing and the use of sophisticated laboratory equipment. To the best of our knowledge, no tools suitable for point-of-care (POC) sensing have been reported. Surface-enha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
19
0
2

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 49 publications
(22 citation statements)
references
References 54 publications
1
19
0
2
Order By: Relevance
“…GSH plays a central role in scavenging reactive oxygen species (ROS) to maintain redox homeostasis [ 37 ]. Sánchez-Illana had determined the GSH peaks by Raman spectra [ 38 ]. Among the wave numbers, a wavelength of 1647 was selected to visualize the GSH distribution.…”
Section: Resultsmentioning
confidence: 99%
“…GSH plays a central role in scavenging reactive oxygen species (ROS) to maintain redox homeostasis [ 37 ]. Sánchez-Illana had determined the GSH peaks by Raman spectra [ 38 ]. Among the wave numbers, a wavelength of 1647 was selected to visualize the GSH distribution.…”
Section: Resultsmentioning
confidence: 99%
“…Surface-enhanced Raman spectroscopy (SERS) (Sánchez-Illana et al, 2018;Yao et al, 2019) is also gaining a lot of attention in recent years because of its great potential in detection of very small concentrations of analytes (down to a single molecule detection). The detection and quantitative determination of GSH have been one of the direct applications of many of the aforementioned new approaches in fluorescence spectroscopy and SERS.…”
Section: Spectroscopic Probes and Sensorsmentioning
confidence: 99%
“…We have performed analytical monitoring with high reliability by using a silver colloid that enhances the GSH signal and allows for the accurate measurement of microvolumes (20 µL) of blood. This novel analytical tool has been validated and is extremely suitable, using a portable optical sensor device to perform point-of-care (POC) testing of OS levels in newborns [58].…”
Section: Biomarkers Of Oxidative Stress Employed In the Clinical Smentioning
confidence: 99%