2003
DOI: 10.1016/s0021-9673(03)00730-1
|View full text |Cite
|
Sign up to set email alerts
|

On-line high-performance liquid chromatography–mass spectrometric detection and quantification of N-acylhomoserine lactones, quorum sensing signal molecules, in the presence of biological matrices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
157
0

Year Published

2005
2005
2014
2014

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 164 publications
(162 citation statements)
references
References 20 publications
5
157
0
Order By: Relevance
“…The mobile phase consisted of a linear gradient (40-95%) of solvent B (methanol with 0.1% formic acid) and solvent A (25 mM ammonium formate with 0.1% formic acid). Effluents were ionized by electrospray ionization under positive mode and detected using the multiple reaction monitoring approach (Morin et al, 2003;Decho et al, 2009). Matrix-matched multiple reaction monitoring experiments were conducted for all 13 standard AHLs (Supplementary Table S1).…”
Section: Chemicalsmentioning
confidence: 99%
“…The mobile phase consisted of a linear gradient (40-95%) of solvent B (methanol with 0.1% formic acid) and solvent A (25 mM ammonium formate with 0.1% formic acid). Effluents were ionized by electrospray ionization under positive mode and detected using the multiple reaction monitoring approach (Morin et al, 2003;Decho et al, 2009). Matrix-matched multiple reaction monitoring experiments were conducted for all 13 standard AHLs (Supplementary Table S1).…”
Section: Chemicalsmentioning
confidence: 99%
“…Linear-quadrupole ion trap devices are capable of secondary mass spectrometry, enabling fine structural investigations of unknown analytes (e.g. Morin et al, 2003;Ortori et al, 2007). Finally, triple quadrupole devices are extremely sensitive and selective; they are capable of operating in a selected reaction monitoring (SRM) mode which allows quantitative observation of specific ions amidst an extremely complex matrix.…”
Section: Analytical Approaches To the Investigation Of Qs In Natural mentioning
confidence: 99%
“…After removal of Na 2 SO 4 crystals by centrifugation , the solvent was evaporated. The samples were then treated as described previously (Morin et al, 2003) and analysed by C 18 reversed-phase HPLC/MS analysis using an Agilent Technologies 1100 system coupled to a Bruker Esquire-LC ESI-MS/ MS positive-ion electrospray ionization and ion-trap mass spectrometer.…”
Section: Methodsmentioning
confidence: 99%