On-line Preconcentration Method for the Determination of Trace Metals in Water Samples Using a Fully Automated Pretreatment System Coupled with ICP-AES

Abstract: An automated on-line sample-preparation method using a computer-controlled pretreatment system (Auto-Pret AES system) coupled with ICP-AES was developed. In this work, an iminodiacetate chelating resin, packed in a mini-column and installed in the system was employed for the collection/concentration of 13 trace metals, including such toxic metals as Be, Cd, Cr, Cu and Pb. The limits of detection of the proposed method for trace metals were in the range of 0.001 (Be) -0.18 (Pb) ng mL -1 . The enrichment factors… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 27 publications
(15 citation statements)
references
References 29 publications
0
15
0
Order By: Relevance
“…For the preparation of the culture medium samples, 0.25 mL of culture medium was diluted to 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 7 [14][15][16]. Briefly, the system consisted of a syringe pump, an 8-port selection valve, and a 6-port switching valve, all of which were controlled by a personal computer using in-house software written by Visual Basic.…”
Section: Methodsmentioning
confidence: 99%
“…For the preparation of the culture medium samples, 0.25 mL of culture medium was diluted to 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 7 [14][15][16]. Briefly, the system consisted of a syringe pump, an 8-port selection valve, and a 6-port switching valve, all of which were controlled by a personal computer using in-house software written by Visual Basic.…”
Section: Methodsmentioning
confidence: 99%
“…An Auto-Pret-AES system equipped with a Muromac A-1 packed minicolumn has also been applied to the determination of 13 trace metals in natural water samples. 25 In this study, an Auto-Pret-GFAAS system has been proposed.…”
Section: Auto-pretreatment System Coupled To Gfaasmentioning
confidence: 99%
“…5. Katarina et al [76] described an on-line hyphenation of sample preparation method by using a computer controlled pre-treatment system (Auto-Pret AES) coupled with ICP-AES for the sample pretreatment and determination of trace metals in water samples. This system enabled determination of trace metals at the ppt level.…”
Section: Hyphenation In Spectroscopymentioning
confidence: 99%