On the high‐resolution mass analysis of the product ions in tandem time‐of‐flight (TOF/TOF) mass spectrometers using a time‐dependent re‐acceleration technique

Abstract: The time-dependent reacceleration of product ions produced as a result of dissociation of a single precursor ion in a tandem time-of-flight mass spectrometer is considered for the first time. Analytical expressions for the shapes of electric pulses bringing all the kinetic energies of the product ions to the same value are derived for two cases: forward acceleration mode and deceleration, followed by re-acceleration in the reversed direction (reversed mode). Secondary time-of-flight focusing resulting from the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 41 publications
0
5
0
Order By: Relevance
“…On the other hand, we could identify two well-known-but opposite-ion optical mechanisms that could have led to the observed signal amplification: first, the used electrode configuration may cause-aside from the intended ion acceleration-a certain spatial focusing of the ion beam, as it was noticed for other electrode configurations beforehand. 11,15,26,32 Second, the negative electrode booster potential may lead to an ion beam divergency. Thus, the positively charged ion cloud would cover a larger area of the active MCP surface, which may be favorable with regard to the relatively long dead time (millisecond range) of the single channels.…”
Section: Booster Amplification Factor For Bsamentioning
confidence: 99%
“…On the other hand, we could identify two well-known-but opposite-ion optical mechanisms that could have led to the observed signal amplification: first, the used electrode configuration may cause-aside from the intended ion acceleration-a certain spatial focusing of the ion beam, as it was noticed for other electrode configurations beforehand. 11,15,26,32 Second, the negative electrode booster potential may lead to an ion beam divergency. Thus, the positively charged ion cloud would cover a larger area of the active MCP surface, which may be favorable with regard to the relatively long dead time (millisecond range) of the single channels.…”
Section: Booster Amplification Factor For Bsamentioning
confidence: 99%
“…Ioanoviciu (1994Ioanoviciu ( , 2000 presented general theoretical analyses. Theoretical calculations for ion mirrors with time-dependent electric fields for the special case of matrix-assisted laser desorption/ionisation (MALDI) have been carried out by Moskovets and colleagues (Moskovets, 1993;Kurnosenko & Moskovets, 2010). Stein (1994) and Short and Todd (1994) described improved time-focusing and energy compensation.…”
Section: Overview Of the Historymentioning
confidence: 99%
“…To achieve acceptable mass resolution for PSD ions which masses typically distributed over broad mass range, these ions are accelerated to energies substantially (Kurnosenko et al, 2010) exceeding the initial energy of precursor ions.…”
Section: Post-source Decaymentioning
confidence: 99%