2023
DOI: 10.3390/c9010027
|View full text |Cite
|
Sign up to set email alerts
|

On the Highly Ordered Graphene Structure of Non-Graphitic Carbons (NGCs)—A Wide-Angle Neutron Scattering (WANS) Study

Abstract: Non-graphitic carbons (NGCs), such as glass-like carbons, pitch cokes, and activated carbon consist of small graphene layer building stacks arranged in a turbostratic order. Both structure features, including the single graphene sheets as well as the stacks, possess structural disorder, which can be determined using wide-angle X-ray or neutron scattering (WAXS/WANS). Even if WANS data of NGCs have already been extensively reported and evaluated in different studies, there are still open questions with regard t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
23
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(23 citation statements)
references
References 67 publications
0
23
0
Order By: Relevance
“…It is worth mentioning that wide-angle neutron scattering (WANS) and the results applied by Osswald et al 16 provide a higher accuracy compared to WAXS analysis (Schuepfer et al 17 17 and this study) and WANS (Osswald et al 16 ) of lignin-derived carbons (this study) and comparable PF-R carbons (Schuepfer et al 17 confined scattering range of s in typical Cu-Kα-WAXS laboratory instruments. 16 Typically, L a is overestimated, and σ 1 shifted to higher values for such typical XRD setups. 16,54 Pfaff et al 54 specified a maximum deviation of approximately 25% as the error range, determining L a with standard laboratory WAXS setups.…”
Section: ■ Results and Discussionmentioning
confidence: 97%
See 3 more Smart Citations
“…It is worth mentioning that wide-angle neutron scattering (WANS) and the results applied by Osswald et al 16 provide a higher accuracy compared to WAXS analysis (Schuepfer et al 17 17 and this study) and WANS (Osswald et al 16 ) of lignin-derived carbons (this study) and comparable PF-R carbons (Schuepfer et al 17 confined scattering range of s in typical Cu-Kα-WAXS laboratory instruments. 16 Typically, L a is overestimated, and σ 1 shifted to higher values for such typical XRD setups. 16,54 Pfaff et al 54 specified a maximum deviation of approximately 25% as the error range, determining L a with standard laboratory WAXS setups.…”
Section: ■ Results and Discussionmentioning
confidence: 97%
“…Yet, valid structure parameters depending on the signal width are only obtained by the applied evaluation technique if at least two reflections of the same lattice plane family caused by intralayer, respectively interlayer, scattering can be fitted precisely, i.e., for instance, the ( 10) and ( 20) reflections. 16 Considering the (00l) reflections, this is not the case, as noted for the (004) reflection. Together with the finite measurement range of standard WAXS laboratory setups limiting the number of recorded reflections, this shows the limitations of possible microstructure evaluation within this study, causing the stacking height L c only to be determined in terms of order of magnitude.…”
Section: ■ Results and Discussionmentioning
confidence: 97%
See 2 more Smart Citations
“…Moreover, the friction between the graphite samples and the transferred graphite is evidently high in the tested trace moisture environment. Due to the similar structure of graphite and non-graphitic (turbostratic) carbon [12,13,57,58] and their similar tribological behavior [22,27,59], it is highly plausible that the poor adhesion between iron uoride and carbon is key to the low friction in the analyzed CF/PTFE -steel tribosystem.…”
Section: Tribological Comparison With Graphitementioning
confidence: 99%