2014
DOI: 10.1002/rcm.7075
|View full text |Cite
|
Sign up to set email alerts
|

On the isobaric space of 25‐hydroxyvitamin D in human serum: potential for interferences in liquid chromatography/tandem mass spectrometry, systematic errors and accuracy issues

Abstract: It was shown in this proof-of-concept study that DMS-MS has the potential to significantly decrease systematic errors, and thus improve accuracy of vitamin D measurements using LC/MS/MS.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
52
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 42 publications
(56 citation statements)
references
References 19 publications
4
52
0
Order By: Relevance
“…TOF-MS experiments (Figure 1a and b) showed high abundances of isobaric compounds, some of which were very close to the m/z value of the precursor ion for 25(OH)D 3 (m/z 401.3414), similar to previous FTICR-MS results [6]. Several of these isobars were of an exogenous nature (Figure 1a), others originated from the serum matrix (Figure 1b).…”
Section: Hrms: Tof-ms Versus Tof-ms/mssupporting
confidence: 85%
See 4 more Smart Citations
“…TOF-MS experiments (Figure 1a and b) showed high abundances of isobaric compounds, some of which were very close to the m/z value of the precursor ion for 25(OH)D 3 (m/z 401.3414), similar to previous FTICR-MS results [6]. Several of these isobars were of an exogenous nature (Figure 1a), others originated from the serum matrix (Figure 1b).…”
Section: Hrms: Tof-ms Versus Tof-ms/mssupporting
confidence: 85%
“…The intensities of some of these isobars were much higher than the signals obtained for 25(OH)D 3 at relevant concentration levels. Although the instrumental resolving power of the QqTOF initially appeared to be sufficiently high, there was a small overlap of the main interference at m/z 401.2666 (C 21 H 33 N 6 O 2 + ; mass measurement accuracy, 1.5 ppm; the same interference was previously observed in the isobaric space of m/z 401 by FTICR analysis of serum samples [6]) from the tail-end of the peak into the 25(OH)D 3 signal. This effect caused isobaric cross-talk from the slightly skewed peaks, which then irreproducibly co-contributed to signal intensities of 25 + ion at m/z 401.3414 and no interference occurred [18].…”
Section: Hrms: Tof-ms Versus Tof-ms/mssupporting
confidence: 54%
See 3 more Smart Citations